Asterion DC Multioutput ASA Series Operational Manual
M330516-01
3-53
Figure 3-46: User V/I Limit Screen
– Channel 3
Entry
Description
Voltage
Sets the power-on default value of voltage user limit in Volts for each
channel. The default is PONS User Voltage Limit.
Current
Sets the power-on default value of output current in Amperes for each
channel. The default is PONS Current Limit.
Power
Sets power-on default value of the output power in watts(W) for each
channel. The default is PONS User Power Limits.
3.4.6.4
C
URRENT
R
EF
M
ODE
Sets the current reference mode to either INT (internal) or EXT (eternal) or
INT+EXT (In external) for the selected channels; refer Figure 3-47. The
default reference mode is internal (INT). If EXT is selected as current reference
mode for selected channel, respected channel voltage settings parameter field
box would be disabled and displayed with text EXT; refer Figure 3-20.
Figure 3-47: Current Reference Mode channel 1
Figure 3-48: Current Reference Mode channel 2