5 - 1
Installation Guide
SDS
Slag Detection System
5.1 Cooling Water Connections
Cooling Water
• Supply must be clean instrument water
• Flow Rate: 1 l/min / 13 Gal/hr
• Maximum temperature: 40 °C / 104 °F
• Maximum pressure: 600 kN/m / 6 Bar /
100 psi
• pH level: 6.5 to 8.5 pH
• Water hardness must be less than
150 mg/l Calcium Carbonate
Water in
Water Out
Note: Flow can be reversed
Water Hoses (Customer supplied)
• Always use flexible hose to allow
for pan & tilt
• Hose internal diameter: 10 mm /
0.39 in
• Secure to inlet and outlet
connectors on SDS jacket with
suitable clips
Water Supply
SDS