Summary of Contents for Gemco 1995L

Page 1: ...Spec Tech Industrial 203 Vest Ave Valley Park MO 63088 Phone 888 SPECTECH Email sales spectechind com www spectechind com...

Page 2: ...K has checked the accuracy of this manual at the time it was printed Any comments you may have for the improvement of this manual are welcomed AMETEK reserves the right to revise and redistribute the...

Page 3: ...ctor 5 3 4 Number of Outputs 6 3 5 Selecting Number of Outputs 6 3 6 Multiprogram AvailableOnlyon P OptionUnits 6 3 7 Setpoint Formula 7 3 8Multi Program OnlyAvailableon P OptionUnits 7 3 9 Setpoints...

Page 4: ...7 3 Grounding 18 7 4 Incoming Power 19 7 5 Low Level Inputs 19 Chapter 8 Specifications 20 8 1 1995 Micro Set PLS Programmer 20 8 2 Mechanical Relay Single Pole Double Throw 20 8 3 AC Solid State Sin...

Page 5: ...rogrammableLimitSwitch PLS with a convenient keypad for programming each independent output circuit to open or close at thedesiredsettings Thissystemallowsprecisepositioncontroloflinearmotion A1995Lco...

Page 6: ...can be panel mounted The controller consists of a keypad a CPU Board and a Power Supply I O Board The following features are found on the 1995L Micro Set n Display A 3 three digit LED readout and a 10...

Page 7: ...plashing Panel cutouts mounting holes and sizes for each component are shown on Pages 6 and 7 of the 1995L catalogsection The controller should be mounted in the appropriate panel cutout and securely...

Page 8: ...g LDT Wiring for this system is shown in Fig 10 1 Fig 10 2 and Fig 10 3 Chapter 10 Wiring Diagrams This wiring diagram is applicable for all standard 1995 PLSs 2 3 Wiring Instructions Attach the pre w...

Page 9: ...cannotbechanged 3 2 Initialization The following key commands should be entered on the keypad to clear all programmed data upon installation and PRIOR to programming This sequence clearsallprogrammedd...

Page 10: ...ofsix theunitwillstorethenextmultipleofsix 3 6 Multiprogram Available Only on P Option Units The Multiprogram feature allows the storage of multiple sets of output sequences that are preprogrammed bas...

Page 11: ...of programs may need to be reduced Asetpoint is one CIR ON or CIR OFF entry Setpoint Programs 1467 2 Number of Programs x A S T U P T U O 6 S T U P T U O 2 1 S T U P T U O 8 1 S T U P T U O 4 2 S T U...

Page 12: ...ecifiedearlierusing CIR 177 See Section 3 5 Selecting Number of Outputs C Depress The will set the selected relay turn on point D Depress This will set the selected relay turn off point E Multiple ON...

Page 13: ...nts Thisisaccomplishedasfollows A Unitmustbeinthe Program mode B To clear all of the setpoints in the active program depress The active program is the program currently selected using Code 771 See Sec...

Page 14: ...change to the position entered The display and outputs are now synchronizedwiththeactualmachineposition OFFSET ActualMachinePosition ENT 3 14 Reset to Preset Remote Reset to Preset Value This option a...

Page 15: ...ay when the transducer speed exceeds the customer spreprogrammedvalue Themotiondetectorissetbyenteringthefollowing A Unitmustbeinthe Program mode B The motion detect must first be enabled before you c...

Page 16: ...up if a one 1 is entered the unit will power up displayingScaleFactorincrements sec 3 17 Decimal Point Programming Acontinuous nonfloating decimal point may be programmed on the display If a scale fa...

Page 17: ...Outputs CIR 380 or 381 ENT NOTE IfyoutrytodisabletheoutputsintheRunmode theunitwilldisplay EEE 3 18 Enable Disable Outputs During setup the outputs may be enabled or disabled When outputs are selecte...

Page 18: ...be installed for the expansion module to operate Two pairs of pins located in the lower right corner of the expansion module should be jumpered on only the last module in the wiring group See Fig 10 4...

Page 19: ...sinking device 5V DC at 10mA A normally closed momentary open contact button can be wired per Fig 10 1 Fig 10 2 OR Fig 10 3 Chapter 10 Wiring Diagrams to activate the Fault Check circuit and it will...

Page 20: ...heoutputswillbeoffuntiltheproblemis corrected and the fault reset button is pressed and released to reactivate the fault output and return the display and outputs to their normal operation 2 If the fa...

Page 21: ...Fig 10 2 OR Fig 10 3 Chapter 10 Wiring Dia grams forwiringoptions NOTE The 1995 PLS cannot be programmed until the security input has been actuated continuity between 5V DC and Security input and bet...

Page 22: ...relays LDTand all interconnecting cables Once isolated the defective module should be replaced and returned to the factory for repair The1995PLS isdesignedforuseinanindustrialenvironmentandincorporate...

Page 23: ...nd variable speed drives are all devices that generate excessive electricalnoisethroughoutthepowergridinatypicalindustrialenvironment Isolationtransformersor constant voltage type power supplies shoul...

Page 24: ...og LDTo to 10Volt output 4 20mA available as special Logic Fault check and security 5V DC at 10mA May be operated by isolated contact current sourcing or current sinking device OUTPUTS Plug inrelaysli...

Page 25: ...imumLoad 2 Amp DC LoadVoltage Range 5 to 60V DC Leakage Current 2mAMaximum On StateVoltage Drop 1 5VMaximum SurgeCurrent 5A 1 Sec Maximum Min OperationalCurrent 50 mA OperateTime 0 5msMaximum ResetTim...

Page 26: ...t u O y a m y a l e r n o n r u t t n s e o d y a l e r e h t t u b s e t a r e p o 7 r e t p a h C w e i v e R y a l e r e c a l p e R d e l i a f e v a h g n i t o o h s e l b u o r T a t a d s s e...

Page 27: ...a c t u p n i s i h t o t g n i r i w e h t n o e s i o n s t u p n I l e v e L w o L 5 7 n o i t c e S w e i v e r P s t e s e r a g n i m m a r g o r p n e h w s t n i o p l a m i c e d g n i h s a...

Page 28: ...m a r g a i D g n i r i W 0 1 r e t p a h C 3 0 1 g i F R O 2 0 1 n a w o h s l l i w y a l p s i d e h t d e t c e t e d s i t l u a f a d n a d e l b a s i d e b l l i w s t u p t u o l l A E G A S...

Page 29: ...25 Installation and Maintenance Manual Chapter 10 Wiring Diagrams Chapter 10 Wiring Diagrams Fig10 1 WiringDiagram Drawing E0221200...

Page 30: ...Chapter 10 Wiring Diagrams Installation and Maintenance Manual 26 Fig10 2 WiringDiagram Drawing E0198202...

Page 31: ...27 Installation and Maintenance Manual Chapter 10 Wiring Diagrams Fig10 3 WiringDiagram Drawing E0234500...

Page 32: ...Chapter 10 Wiring Diagrams Installation and Maintenance Manual 28 Fig10 4 WiringDiagram Drawing E0204400...

Page 33: ...1284 01 03 Z108 5C 1080 N Crooks Road l Clawson MI 48017 800 635 0289 l 248 435 0700 l Fax 248 435 8120 www ametekapt com l www ametek com...