Ametek DR454RD Service And Parts Manual Download Page 5

 

Revised – June 2016

 

6)  Remove  the  housing  bolts  and  remove  the  motor  assembly  (arbor/.housing  on  remote  drive 

models). 

7)  Arbor disassembly (Applicable on remote drive models only): 

a)  Slide the bearing retraining sleeve off the shaft at the blower end. 

b)  Remove the four (4) screws and the bearing retaining plate from the blower end. 

c)  Lift the shaft assembly far enough out of the arbor to allow removal of the blower end snap 

ring. 

d)  Remove the shaft assembly from the arbor. 

e)  If necessary, remove the shaft dust seal from the pulley end of the arbor. 

 

Muffler Material Replacement: 

1)  Remove the manifold cover bolts and them manifold cover. 
2)  The muffler material can now be removed and replaced if necessary.  On blowers with fiberglass 

acoustical wrap the tubular retaining screens with the fiberglass matting before sliding the muffler 

pads over the screens. 

3)  Reassemble by reversing the procedure. 

NOTE:    On  DR068  models  with  tubular  mufflers  it  is  necessary  to  remove  the  cover  and 

impeller accessing the muffler material from the housing cavity. 

Blower Reassembly: 

1)  Place the assembled motor (assembled arbor assembly for remote drive models) against the rear 

of the housing and fasten with the bolts and washer. 

2)  To ensure the impeller is centered within the housing cavity re-shim the impeller according to the 

procedure outlined below. 

3)  If blower had a seal replace the seal with a new one. 
4)  Place the impeller onto the shaft making sure the shaft key is in place and fasten with the bolt, 

washer and spacer as applicable.  Torque the impeller bolt per the table below.  Once fastened 

carefully rotate the impeller to be sure it turns freely. 

5)  Replace the cover and fasten with bolts. 
6)  Reconnect the power leads to the motor per the motor nameplate. 

 

Bolt Size 

Torque 

Pound-Force-Foot 

1/4-20 

6.25 +/- 0.25 

5/16-18 

11.5 +/- 0.25 

3/8-16 

20.0 +/- 0.5 

½-13 

49.0 +/- 1 

5/8 –11 

90.0 +/- 2 

 
 
 

Summary of Contents for DR454RD

Page 1: ...TS MANUAL FOR BLOWER MODEL DR454RD DR656RDNT REMOTE DRIVE REGENERATIVE BLOWER AMETEK Dynamic Fluid Solutions 100 East Erie St Kent Ohio 44240 Telephone 330 673 3452 Fax 330 677 3306 email dfs informat...

Page 2: ...ures due to abuse misuse misapplication or repeat offense will not be covered AMETEK Rotron will then notify you of your options Any failed unit that is tampered with by attempting repair or diagnosis...

Page 3: ...at the blower outlet or inlet Also if problems do arise the Rotron Field representative will need to know the operating pressure suction to properly diagnose the problem 6 Excess Air Bleed excess air...

Page 4: ...and add filter 3 Change bearings Performance Below Standard 1 Leak in piping 2 Piping and air passages clogged 3 Impeller rotation reversed 4 Leak in blower 5 Low voltage 1 Tighten 2 Clean 3 Check wir...

Page 5: ...er pads over the screens 3 Reassemble by reversing the procedure NOTE On DR068 models with tubular mufflers it is necessary to remove the cover and impeller accessing the muffler material from the hou...

Page 6: ...the flange face to the motor shaft shoulder B Impeller Thickness C Measurements A and B are made by laying the parallel bar across the housing flange face and measuring to the proper points Each meas...

Page 7: ...ASSEMBLY DRAWING DR454 DR505 DR513 DR555 DR606 DR656 REMOTE DRIVE BLOWERS...

Page 8: ...Used 15 1 510629 510629 510629 510629 510629 510629 16 1 510355 510355 510355 510355 510355 510355 17 1 120203 120203 120203 120203 120203 120203 18 1 120214 120214 120214 120325 120262 See Next Page...

Page 9: ...Used Not Used Not Used Not Used Not Used 36 Not Used Not Used Not Used Not Used Not Used Not Used 38 1 511441 511441 511441 511441 511441 511441 Item No 11 11 10 11 10 11 3 6 6 11 18 3 5 6 11 18 DR65...

Page 10: ...Not Used Not Used Not Used 550305 551425 550249 8 pcs 155236 510356 510357 510358 510359 Not Used 510629 510355 120203 155101 Not Used 511446 511440 251791 Not Used 511442 529191 510217 511444 140004...

Page 11: ...DR656RDNT 080610 251207 140009 Not Used 511443 Not Used Not Used Not Used 511441 As needed Viewed looking at inlet outlet ports 5 31 16 Rev J...

Reviews: