Isolated Analog Programmer Operation
DLM-E Series and DCS-E Series
2.3.4 Resistance
Programming of Output Voltage
SW1 Switch Settings
SW1-1 ON (1) = 0–5K
2
9
12
13
1
25
21
14
Set up for resistance programming of the output voltage as follows:
1.
Set SW1-1, V PROG, to ON (1) for 0-5VDC programming range.
2.
Connect the external programming resistance, 0-5k
Ω
, to the ISOLATED ANALOG
PROGRAMMER connector, J4, from Pin-9 to Pin-12.
3.
Connect a jumper from Pin-21 to Pin-9 to connect the 1mA current source.
4.
Connect Pin-1, ANALOG-CONTROL, of the ISOLATED ANALOG PROGRAMMER
connector, J4, to Pin-2 to enable remote control.
5.
Program the other parameters to the desired limit values.
2-10
M51A Option