193111-079
OPTIONS
7-2 March 7, 2008
For series charging, both batteries must be at identical
depths of discharge (DOD); ie, they are used in series
in the vehicle. A mismatch in DOD of the two batteries
will result in severe overcharge of the lightly discharged
battery and severe undercharge of a deeply, dis-
charged battery.
Operate this charger as instructed in Operation chapter
of this manual, except that charger must be connected
to both batteries instead of just one. Refer to
Figure 7-2.
CAUTION: Make sure all connections are made
positive to positive and negative to negative as
shown.
Remote Charge Control –
Option 101
This option provides a separate remote control box
containing charger’s Charge Control.
This remote control box must be connected to charger
as instructed on label provided with remote charge
control. Closely observe wire color coding.
Operate this charger as instructed in Operation chapter
of this manual and as instructed under any applicable
option descriptions.
Fused Disconnect Switch –
Option 500
(Refer to Figure 7-3)
This option is provided to meet certain “JIC” require-
ments. The switch must be in the open (OFF) position
to disconnect all AC power into charger and to allow
front door to be opened. With switch in open position,
door can be opened by turning slotted latch screw to
the left.
Disconnect switch is for
emergency
or
service use
only.
Charge cycle should continue until automatically shut
off. If cycle must be interrupted, turn timer to “OFF” or
push “STOP” button.
A control circuit operating on 24 volts is also provided
to help assure operator safety.
Figure 7-2 Series Charging Connections
Figure 7-3 Fused Disconnect Switch