background image

Water Cooled Mountings

Installation Guide

SPOT

8

3)  Insert the SPOT Thermometer 

into the Water Cooled 

Mounting and secure it in 

place with the Sprung retainer 

clip (Fig. 3-3).

4)  Unscrew the cable gland shell 

and split bush from the Water 

Cooled Mounting.  Slide the 

PoE Cable through the gland 

shell and fit the split bush 

between the gland shell and 

the connector (Fig. 3-4).

5)  Slide the PoE Cable through 

the cable gland and attach it 

to the Thermometer connector 

(Fig. 3-5). 

6)  Slide the split bush into the 

cable gland and tighten the 

gland shell.   Make sure that 

the cable is not stretched.  Do 

not over-tighten the gland 

shell.

7)  Close the hinged Back Cap 

and secure it in place with the 

fastener (Fig. 3-6).

 

The Thermometer is now 

installed in the Water Cooled 

Mounting.

If you are using an Analogue 

Cable in addition to (or instead 

of) the PoE cable, refer to 

Section 3.1.

Fig. 3-3

Sprung retainer clip

Fig. 3-4

Fig. 3-6

Fig. 3-5

Summary of Contents for 808100

Page 1: ...WATER COOLED MOUNTINGS including Sealed to Process variant i SPOT INSTALLATION GUIDE PUBLICATION NO 808274 LANGUAGE ENGLISH Q U A L I T Y C U S T O M E R S O L U T I O N S...

Page 2: ...sponsibility of the assembler Protective Clothing Face and Eye Protection It is possible that this equipment is to be installed on or near to machinery or equipment operating at high temperatures and...

Page 3: ...gn and Manufacturing Standards The Quality Management System of Land Instruments International is approved to BS EN ISO 9001 for the design manufacture and on site servicing of combustion environmenta...

Page 4: ...oled Jacket Installation Dimensions 2 1 2 Pan Tilt Mounting Installation Dimensions 3 2 Air Water Specifications 5 2 1 Maximum recommended limits 5 2 2 Maximum ambient temperature 5 3 Installing the S...

Page 5: ...INSTALLATION DIMENSIONS 1...

Page 6: ...Water Cooled Mountings Installation Guide SPOT 2 1 Installation Dimensions 1 1 Water Cooled Jacket Installation Dimensions...

Page 7: ...3 SPOT Water Cooled Mountings Installation Guide 1 2 Pan Tilt Mounting Installation Dimensions...

Page 8: ...AIR WATER SPECIFICATIONS 2...

Page 9: ...C 113 F Outlet water temperature 50 C 122 F 2 2 Maximum ambient temperature The maximum ambient temperature depends on water inlet temperature and flow rate See Fig 2 1 300 572 250 482 200 392 150 30...

Page 10: ...INSTALLATION 3...

Page 11: ...e Cable port If you want to use an Analogue cable you will need to replace the Blanking Plug with a Large Connector Sealed Gland M25 Land Part N 810481 available from Land Instruments International Re...

Page 12: ...ector Fig 3 4 5 Slide the PoE Cable through the cable gland and attach it to the Thermometer connector Fig 3 5 6 Slide the split bush into the cable gland and tighten the gland shell Make sure that th...

Page 13: ...ion 3 Slide the Analogue Cable connector through the gland outer shell and the seal washer Fig 3 7 4 Fit the split bush between the washer and the main body of the gland 5 Insert the Analogue Cable in...

Page 14: ...Blank...

Page 15: ...Blank...

Page 16: ...1DJ England Tel 44 0 1246 417691 Email land enquiry ametek com www ametek land com AMETEK Land Americas 150 Freeport Road Pittsburgh PA 15238 U S A Tel 1 412 826 4444 Email irsales ametek com www amet...

Reviews: