BEFORE INSTALLATION OF YOUR APPLIANCE  

Firstly  check  all  local  building  and  heating  regulations.  Different  states  and  different  localities  have  varying  regulations 
about the installation and operation of wood stoves and you or your installer should be aware of these. 

 
POSITIONING THE AMESTI

 

We  enclose  a  sheet  showing  approved  distances  from  the  heater  to  combustible  side  and  back  walls.  This  also  gives 

details  of  the  floor  protector  size.  These  clearance  distances  can  only  be  reduced  if  the  surrounding  walls  or  floor  are 
made of noncombustible material (stone, brick or concrete). 

 

CONSTRUCTING THE FLUE

  

A free standing appliance should have a flue kit made of stainless steel or requirement of AS/NZS2918/2001. The length 
will depend on ceiling height and roof design but the top of the flue pipe must penetrate the roof line by a minimum of 

1m or to be in excess of 3m from the roof in a horizontal line, or a minimum of 600mm higher than the ridge if within 3m 
of the ridge. 
If the draft is insufficient or periodic down drafting occurs and the appliance smokes or only burns slowly, extending the 

flue or fitting a specialized cowl will usually cure it. 
In the roof  cavity and above the roof  it is essential that the flue has two outer casings as it is important to prevent 

condensation  on  the  upper  cooler  parts  of  the    flue  as  well  as  being  a  safety  feature.  Where  the  flue  penetrates  the 
ceiling and roof, it must comply with AS/NZS2918/2001. If the stove is fitted into and existing chimney ensure that it is 

sealed at the base of the chimney  with a register plate and install the flue lengths up the chimney to atmosphere and fit 
the appropriate termination chimney plate and cowl. 
The flue kit must be installed according to the manufacturer’s instruction. 

 

Summary of Contents for Nordic 360

Page 1: ...N OPERATION INSTRUCTION Models Nordic 360 Nordic 380 Nordic 450 KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE Manufactured in Chile Jos Miguel Carrera n 6 los Libertadores Colina Santiago Chile Nordic...

Page 2: ...of the flue pipe must penetrate the roof line by a minimum of 1m or to be in excess of 3m from the roof in a horizontal line or a minimum of 600mm higher than the ridge if within 3m of the ridge If th...

Page 3: ...leaving space behind it for air circulation Main Flue Stainless steel It extends from the top of the fireplace to the cowl Celing plate Stainless steel Distance from flammable Material Any flammable m...

Page 4: ...190 355 Note these clearances are for heat sensitive materials Clearance from heat resistant walls e g brick or stone can be 100mm A heat resistant floor e g concrete slab with slate needs no floor p...

Page 5: ...caught fire add some larger pieces of wood Load the wood into the firebox so that the logs are placed at right angles to the door opening Close the door and make sure the top air control is fully ope...

Page 6: ...braided rope If it should need replacing fix it in its groove with silicone mastic 4 Fire Bricks The bricks should last many years but if any need replacing they can be placed in position vertically...

Page 7: ...ifespan that will depend on the intensity of use and the quality of wood used The 1 year warranty will cover the damper against cracking of material and failures of welded joint but not the wear and t...

Reviews: