background image

ARI-500 Automatic Band Switch for ALS-500/600 

Instruction Manual 

 

The ARI-500 receives band information over the serial interface, while amplifier keying comes from the remote port.  The serial 
communications settings are 9600 bps and the linear amplifier relay must be turned on and must be setup on the radio for the ARI-500 
to function properly.  The serial communications setting is 

Menu 56

 and needs to be set to 

9600

.  The amplifier relay setting is 

Menu 

28

 and should be set to option ‘

2

’. 

 
Operation 

  
Set the amplifier’s Frequency Select Switch to the REMOTE position.  The amplifier frequency band will now be controlled by the 
transceiver through the ARI-500.  The amplifier will also now be keyed through the ARI-500.  The relay jack on the back of the 
amplifier is not used.  The green PWR LED and the red LINK LED will glow steadily when the ARI-500 amplifier interface cables 
are connected properly and data is being received from the transceiver.  If the transceiver is off or data is not being sent, the PWR 
LED will flash on for about one second when amplifier power is turned on, and the LINK LED will flash continuously 
 

Toggle Switch:   This switch in the down position will place the amplifier into standby.   Up position  will  place amplifier into 
operate.   Note:  This switch must be in the down position when powering up the ALS-1300 to prevent a load fault command. 

 

Note:

  The ALS-600 will be placed in OPERATE whenever keying is applied through the ARI-500 regardless of the STANDBY-

OPERATE switch position on the amplifier.  If the ALS-500RC Remote Control Head is used, the ALS-600 may be taken off 
line with the ALS-500RC POWER switch (ARI-500 JMP2 must be strapped 2-3, FIGURE B, when the ALS-500RC is used). 

 

Note:

  JMP 2 

MUST

 be in the Factory Default position (FIGURE A) if the ALS-500RC Remote Control Head is 

NOT

 used. 

 
The ALS-500M/600 Power On/Off switch operates the same as without the ARI-500M.  If the Remote ALS-500RC is used, refer to 

Operating the ALS-500RC with the ARI-500

.   

 
The ARI-500 has an Auto Reset for the amplifier’s load fault (O/L).   When the amplifier goes into load fault mode, the ARI-500 will 
wait 5 seconds and then reset the amplifier’s LOAD FAULT circuitry by cycling the ALS-500M amplifier’s power OFF and back ON 
(the ALS-500M amplifier’s power switch must be in the OFF position for the Auto Load Fault reset to work), or by remotely cycling 
the ALS-600 OPERATE/STANDBY function.   The ARI-500 will reset the amplifier overload up to 3 times in a 5-minute period.   If 
the amplifier load faults more than 3 times in a 5 minute period, the amplifier’s power must be manually switched off to reset.  Strap 
JMP3 to OFF to disable the Auto Reset feature (see Figure C).    
 

Note:

  If Auto Reset is disabled, power must be manually cycled on both the ALS-500M and ALS-600 to re-set the load fault circuitry 

(or cycle the POWER switch on the ALS-500RC if used). 

  

Note:

  When the ALS-500RC is used with the ARI-500, the ARI-500 Auto Reset feature is automatically disabled.  Manual reset is 

performed with the ALS-500RC POWER switch.  Strap JMP3 to OFF (Figure C). 

 
22.5 to 30 MHz (10/12 Meter) Operation 

  
The ARI-500 has a jumper labeled JMP1.  JMP1 is for operation on frequencies between 22.5 and 30 MHz (AUX).  The factory 
default is in the OFF position.  The OFF position prevents the amplifier from operating when the transceiver is in the 10/12 Meter 
band.  Move JMP1 to ON if the amplifier has the 12/10 Meter kit installed.  See Fig C.     

  

 
 
 
 
 
The PWR and Link indicator lights illuminate steadily when the transceiver and amplifier are connected and turned on.  The red LED 
marked LINK will blink rapidly if the ARI-500 RADIO jack is not receiving information from the transceiver. 

 
 
 
 
 
 
 

Note About Kenwood Radios 

Since the Radio Control Port is used to get the band information from the radio, the radio must be switched on first 
before powering up the ARI-500. Upon power up, the ARI-500 sends the Auto Information (AI) command to the 
Kenwood radio. This instructs the Kenwood to send the radio’s status information anytime it changes. Failure to do this 
will result in the radio not receiving this command and the ARI-500 not detecting a properly connected radio.  Anytime 
the status of the radio changes, there is a one second delay before the new information is sent over the serial line to the 
ARI-500. This causes the switch to appear to respond slowly to the band changes. This is a result of the delay from the 
Kenwood radio, 

NOT

 the ARI-500.  

Note:  Kenwood Com Port pins 7 & 8 must be connected together.

 

 

ON 

OFF 

JMP 1 (12/10 Meter Enable) 

JMP 3 (Auto LOAD FAULT re-set) 

FIGURE C 

Summary of Contents for ARI-500

Page 1: ...AMERITRON ARI 500 AUTOMATIC BAND SWITCH FOR THE ALS 500M ALS 600 AMPLIFIERS INSTRUCTION MANUAL AMERITRON 116 WILLOW ROAD STARKVILLE MS 39759 USA 662 323 8211...

Page 2: ...e ARI 500 is designed to automatically select the correct frequency range on these amplifiers by reading the frequency information or band data from the transceiver This automatic switch is compatible...

Page 3: ...e 1 2 position Fig A Factory default Must be strapped this way when the ALS 500RC is NOT used 2 JMP 2 in the 2 3 position Fig B Strapping position when using the ALS 500RC The Current RF Power Meter P...

Page 4: ...he connections required between ICOM radios and the ARI 500 Connection to an ICOM IC 7000 requires an ICOM approved modification Follow the instructions in your IC 7000 user s manual page 140 to make...

Page 5: ...e correct Band Data connections Please note that Pin 8 on the Yaesu connector TX INH must be connected to ground Pin 3 on the FT MP 2000 9000 series of radios This connection is optional on the FT 857...

Page 6: ...RI 500 is first turned on the Auto Information AI command is sent to the radio This command causes the Kenwood radio to output the state of the radio frequency mode etc anytime the state has changes T...

Page 7: ...ear View of Kenwood Transceiver The Kenwood TS 480 requires different connections See the Addendum in the rear of this manual Kenwood TS570 870 2000 Interface to ARI 500 Connection ARI 500 Radio Input...

Page 8: ...uitry by cycling the ALS 500M amplifier s power OFF and back ON the ALS 500M amplifier s power switch must be in the OFF position for the Auto Load Fault reset to work or by remotely cycling the ALS 6...

Page 9: ...ARI 500 manual radio manual and information about your station available during the call We strongly recommend calling Ameritron with any questions but questions can also be mailed directly to Ameritr...

Page 10: ...ARI 500 Automatic Band Switch for ALS 500 600 Instruction Manual 10 Schematic...

Page 11: ...ARI 500 Automatic Band Switch for ALS 500 600 Instruction Manual 11...

Page 12: ...ARI 500 Automatic Band Switch for ALS 500 600 Instruction Manual 12...

Page 13: ...Card 2 Notify Ameritron or its nearest authorized service facility as soon as possible after discovery of a possible defect of a the model number and serial number if any b the identity of the seller...

Reviews: