Most non-amateur services prohibit use of non-commercial radio equipment. This
amplifier automatically prevents operation between 25 and 28 MHz. Operation in the 25-
28 MHz range is not available with this product, irrespective of licensing or end-use.
Warning Lights
The ALS-606 has two primary warning lights in the center of the front panel, SWR and
PA. When SWR or PA warnings illuminate from an operating fault the amplifier defaults
to a forced bypass mode. Operational faults and the forced bypass reset by placing the
amplifier in standby.
ALC:
The yellow ALC light is at the far left of the warning light cluster, next to the ALC
control. The yellow ALC light is not a fault indicator. The ALC light indicates ALC output.
Occasional flashing is normal with properly adjusted ALC. An almost steady ALC light
generally indicates too much ALC.
TX
: The TX indicator illuminates steady green when the amplifier is “keyed” or in the
transmit mode.
The SWR and PA indicators serve exclusively as warnings. The SWR and PA, in
conjunction with TX and Band indicators, flash in certain “codes” to indicate severe
operational problems.
The following table applies to faults:
Warning
light Steady
Warning
light Flash
Fault
Cause or Cure
SWR
TX
Antenna
Reflected
Power
High
antenna
SWR
or
intermittent antenna or feed line
connection
SWR, PA
Band
Wrong filter
Filter input SWR
Exciter
or
amplifier
on
incompatible band, filter failure
PA, TX
PA FET too hot
Excessive power for duty cycle
or SWR, lack of proper airflow
10M,
PA,
TX
Illegal 11 meter
Excessive 27 MHz signal level
REM, PA
No data or bad band
data when on remote
Defective or improper remote
cable, or bad radio band data
information
Table 3 LED Alarm Indicators
Summary of Contents for ALS-606
Page 1: ......
Page 2: ...Version 0A 2 Notes...
Page 12: ...Version 0A 12 Figure 1 Quick Starts Typical Wiring...
Page 21: ...Version 0A 21 Interconnection Wiring Figure 2 Amplifier Interconnection...
Page 32: ...Version 0A 32 Schematics Filter 1KWF6 Figure 7 1KWFL6 Filter Board...
Page 35: ...Version 0A 35 Metering Board MB2 Figure 12 Meter Board MB2...
Page 38: ...Version 0A 38 ALS 600PS Power Supply Figure 16 ALS 600PS Power Supply...
Page 39: ...Version 0A 39 Figure 17 ALS 600PS Board...
Page 43: ...Version 0A 43 NOTES...