7. Maintenance                                                                                                                                         

The following maintenance measures are recommended to ensure optimum performance of 
the modules: 

 

  Under most weather conditions, normal rainfall is sufficient to keep the glass surface of 

modules clean. Clean the glass surface of the module as necessary.   

 

  Always use clean water and a soft sponge or cloth for cleaning.   

 

  If snow accumulates on top of the modules, remove the excess snow gently from the 

surface of the modules using a brush or broom. 

 

  Check the electrical and mechanical connections periodically to make sure that all 

connections are tight, secure, intact and free of corrosion. 

 

  Do not try to change the components of module (Junction box, bypass diode and 

connector). 

 

  If any problem arises, consult a professional for suggestions. 

8. Disclaimer of liability                                                                                                                         

Because the use of this manual and the conditions or methods of installation, operation, use 

and maintenance of the product are beyond Amerisolar

’s control, Amerisolar does not accept 

responsibility and expressly disclaims liability for loss, damage, or expense arising out of or in 

any way connected with such installation, operation, use or maintenance. 

No responsibility is assumed by Amerisolar for any infringement of patents or other rights of 

third parties, which may result from use of the product. No license is granted by implication or 

otherwise under any patent or patent rights. 

The information included in this manual is based on Ameris

olar’s knowledge and experience 

and  is  believed  to  be  reliable;  but  such  information  including  product  specification  (without   

limitations)  and  suggestions  do not  constitute  a  warranty,  expresses  or  implied.  Amerisolar 

reserves the right to change the manual. 

 

 

 

 

 

 

 

 

 

Summary of Contents for AS-6P

Page 1: ...Worldwide Energy and Manufacturing Nantong Co Limited Installation Manual of Solar Module...

Page 2: ...ng 1 4 Product identification 2 5 Mechanical installation 2 5 1 Climate condition 2 5 2 Site selection 2 5 3 Module tilt angle 3 5 4 Installation methods 3 6 Electrical installation 5 6 1 Module wirin...

Page 3: ...liance with all local and national applicable standards codes and regulations Installers should assume all risks of injury that might occur during installation including but not limited to the risk of...

Page 4: ...ar modules should be installed in the following conditions Ambient temperature 20 C to 40 C Operating temperature 40 C to 85 C Storage temperature 40 C to 40 C Humidity below 85RH Wind load below 2400...

Page 5: ...optimum winter performance As a rule if the system power production is adequate in winter it will be satisfactory during the rest of the year Optimal tilting of the module is roughly the same as the l...

Page 6: ...from the module clamps The module frame is not to be modified under any circumstances When choosing this type of clamp mounting method please be sure to use at least four clamps on each module two cla...

Page 7: ...uce more current and or voltage than reported at standard test conditions The suggested fuse must be used for overcurrent protection Accordingly the values of Isc and Voc marked on this module should...

Page 8: ...ontinuously using a suitable grounding conductor The grounding conductor or strap may be copper copper alloy or other material acceptable for use as an electrical conductor a Grounding by using ground...

Page 9: ...mounting with tightening the binding bolt of the grounding wire Fig 6 Grounding method b c Additional third party grounding devices The modules can be grounded using third party grounding devices so...

Page 10: ...consult a professional for suggestions 8 Disclaimer of liability Because the use of this manual and the conditions or methods of installation operation use and maintenance of the product are beyond A...

Page 11: ...um Series Fuse Rating W V A V A V A AS 6P18 160 23 22 8 90 18 90 8 47 1000 15 165 23 29 9 15 18 97 8 70 1000 15 AS 6P21 185 27 09 8 82 22 05 8 39 1000 15 190 27 15 9 04 22 11 8 59 1000 15 AS 6P24 210...

Reviews: