as possible and that there are no dips, loops, low spots or kinks. 

(See D in Figure 2 above)

Also, to reduce noise, assure that RO drain line enters the vertical pipe from a direction other 

than the direction of entry of the garbage disposal pipe.

SINK WITHOUT DISPOSAL

Best choice is the vertical pipe about 4” above the water level in the trap.

To Install 

Drill a 3/8” hole through one side of the drainpipe. Align the hole in the drain clamp 

with the hole in the drainpipe. Tighten down the drain clamp snuggly so it will not move on 

drain pipe.

STEP 5 STORAGE TANK PREPARATION

1. Wrap the threads on top of the tank with 6 3wraps of Teflon tape 

(do not use any type of

pipe compounds)

.

2. Screw tank ball valve onto the top of the tank 

(approximately 4 to 5 full turns - 

do NOT

over-tighten).

 Check for leaks once RO is pressurized and while tank is filling and again

when tank is full.

3. Tank is pre-charged with air pressure. Tank can be laid on its side if necessary 

(tank will

hold approximately 2 to 3 gallons of RO water depending on water pressure, tank position-

ing, and tank air pressure).

4. Tank pressure can be increased to improve water flow to the faucet or refrigerator. Air

pressure can only be tested when tank is completely empty of water. Air pressure of 5-PSI

minimum, 12-PSI maximum is recommended. The higher the air pressure the smaller the

volume of water the tank will hold. Pressure of 10-12 PSI may be necessary to feed a line

to the refrigerator. 

Over pressurizing may ruin the tank.

STEP 6 TUBING CONNECTIONS

IMPORTANT: Fitting manufacturer requires fittings to be re-checked after system reaches 

full operating pressure and temperature, Re-tighten and secure as necessary.

1.

¼” White Supply Tube on Filter Pac/RO module

 Connect the supply (white) tube firmly

into the push-in port on the side of the easy tap adapter installed on the cold water supply

line. 

Optional If self-piercing valve is used, connect to valve using brass nut, tubing sup-

port, and ferrule, (not included).

2.

¼” red Drain Tube on FilterPac RO Module

 

Air-Gap faucet system

 Use the coupler

from the parts bag to connect the ¼” red drain tube from the faucet to the red tube from

Filter Pac/RO Module. 

(See C in Figure 2 on page 6)

. Push firmly so tubes will not pull out

of coupler or leak.

FIGURE 2

NO DIPS

in LINE

Red line connects to RO drain line

Faucet supply from RO system

C

D

Summary of Contents for ET6500GRO

Page 1: ...07 15 RO Manual A Owners Manual FOR REVERSE OSMOSIS SYSTEMS MODEL ET6500GRO P N 10 02 1330GRO Includes Installation and Service Procedures Specifications and Operation Guidelines ...

Page 2: ...Benefits 2 Specification Limitations 2 Warnings 3 Photo of ROs and Contents List 4 Installation Procedures 4 System Position 4 Faucet Installation 4 Figure 1 Diagram 5 Easy Tap Adapter Installation 5 Drain Saddle Clamp Installation 5 Figure 2 Diagram 6 Storage Tank Preparation 6 Tubing Connections 6 System Start Up Procedures 7 Refrigerator Icemaker Hookup 8 Recommended Filter Service Life 7 Filte...

Page 3: ... coolers 16 Bottled Water CONTENTS OF PACKAGE 1 Filter Pac RO module 2 Storage Tank 3 Owner s Manual 4 Warranty Registration Card 5 Standard air gap faucet or optional col ored faucet 6 Parts Bag Easy Tap Adapter w washer plastic Drain Clamp black plastic Coupler plastic for use w air gap faucet Faucet Adapter plastic 7 16 fip 3 8 push Tank Ball Valve Mounting Screws 7 Water quality monitor TOOLS ...

Page 4: ...drain line gets plugged from obstruction in the drain line 9 Water containing iron in excess of 1ppm will require some pretreatment Consult your local water authority 10 This reverse osmosis system contains a replaceable component critical to the efficiency of the system Replacement of the reverse osmosis component should be with one of identical specifications as defined by the manufacturer to as...

Page 5: ...the Filter Pac RO module and that the mounting screws will not pierce through the wall Hang Filter Pac RO module to assure sufficient space is allowed Remove Filter Pac RO module from the wall for now and continue with install STEP 2 FAUCET INSTALLATION 1 Check for an extra hole in the sink You must drill a 1 hole for the faucet if the sink does not have one Determine Location of Faucet Hole Check...

Page 6: ...cation of Drain Clamp SINK WITH DISPOSAL Select location to place drain saddle clamp Best choice is the vertical pipe as near the sink as possible making certain that the drain clamp is above the horizontal garbage disposal waste pipe When connecting the black drain tube to drain saddle clamp keep the tube run as straight FIGURE 1 countertop faucet stem B A F slot washer white spacer washer lock w...

Page 7: ...nd tank air pressure 4 Tank pressure can be increased to improve water flow to the faucet or refrigerator Air pressure can only be tested when tank is completely empty of water Air pressure of 5 PSI minimum 12 PSI maximum is recommended The higher the air pressure the smaller the volume of water the tank will hold Pressure of 10 12 PSI may be necessary to feed a line to the refrigerator Over press...

Page 8: ...refill and drain again in 4 to 6 hours The RO system is shipped with a food grade preservative and must be flushed out prior to use DO NOT DRINK THE RO WATER UNTIL TANK HAS BEEN DRAINED TWICE 3 Shut RO faucet off and let system fill again RO water is now ready for use IMPORTANT Check carefully for small leaks every few hours for the first few days to assure there are no leaks It is wise on any RO ...

Page 9: ...pending on influent water quality and hardness See Performance Indicator information listed below Carbon Post filter Carbon MAP Filter These filters need to be changed at least every 12 months to insure quality water Do not wait until taste is a problem Performance indicator The RO system contains a replaceable treatment component criti cal for effective reduction of TDS Total Dissolved Solids The...

Page 10: ...in off po sition Remove old pre filters and membrane from housings Remove the post filter On the ET5000 a 3 8 union and on the ET6000 a 3 8 reducer union not included will be necessary to reconnect the tubing together without the post filter installed during sanitizing procedures 4 Carefully put 2 capfuls of household bleach into the empty filter bowl canisters Re install filter bowls without filt...

Page 11: ...1404 1 JG 90 Ball Valve 2 804 11 04 Hex Nipple 1 419 1406 3 8 JG 90 Ball Valve Storage Tank 2 3 805 40 02 Fitting mpt JG Elbow ET6000 1 123 541 Water Conservation Shut Off Valve 1 138 150GRO 50 GPD GRO Membrane 1 128 R O ring Membrane Housing 2 805 40 04 Fitting 1 8 mpt JG Elbow 1 121 1604 1 Check Valve Fitting 1 8 mpt JG Elbow 1 129 260 Flow Restrictor 260 ml 1 110 03181 3 2 Gallon Storage Tank 1...

Page 12: ...s of water If just air will float to surface and dissipate System is still new This is normal and should clear up in two weeks Noisy drain or faucet Air gap faucet A little noise is common with air gap faucets Check manual to be sure installed in proper location Allow two weeks for air to work out of system Drain tube Check that drain tube from faucet is continuously down hill to drain Loops or di...

Page 13: ... If damaged replace tube System is con tinually running Shut off valve not working Replace shut off valve Low city supply water pressure Increase water pressure to 40 PSI with a pump Bad check valve Replace check valves Ice being made in refrigerator Nothing you can do ice is made on demand System is new Allow 2 weeks for air to bleed Ice maker not working Ball valve to ice line is off Turn on bal...

Page 14: ...e product water shall be tested regularly to verify that the system is perform ing properly Testing can be accomplished by contacting the service company that installed your RO system or an authorized dealer If a service company is not available in your area a water sample may be sent to AmeriFlow for a free TDS test of your RO water Additionally a water quality monitor is available for purchase f...