background image

WILLIAMSBURG  ELITE™ 5’ INTEGRAL APRON

WHIRLPOOLS BY AMERICAN STANDARD

HIGH GLOSS ACRYLIC

© 2003 American Standard Inc.

NOTES:

BATH CAN BE INSTALLED EITHER ABOVE OR BELOW FLOOR LINE AS PIER, ISLAND, OR PENINSULA TYPE
INSTALLATION. SUPPORT OF BATH BY SUMP BEDDING. SUPPORT AND ENCLOSING MATERIAL BY OTHERS.

REFER TO INSTALLATION INSTRUCTIONS SUPPLIED WITH WHIRLPOOL FOR ADDITIONAL INFORMATION.

FITTINGS NOT INCLUDED AND MUST BE ORDERED SEPARATELY.

PROVIDE SUITABLE REINFORCEMENT FOR ALL SUPPORTS.

IMPORTANT:

Dimensions of fixtures are nominal and may vary within the range of tolerances established by ANSI Standard Z124.1
These measurements are subject to change or cancellation. No responsibility is assumed for use of superseded or
voided leaflet.

21-1/4

(540mm)

REF.

DIM

1" WATER

RETENTION

FLANGE

(3 SIDES)

21-1/2

(546mm)

1-1/2 O.D.TAILPIECE

BATH

SUPPORT

MATERIAL

LEVELING STRINGER

NOT FOR SUPPORT 

ROUGH

FLOOR

FINISHED

WALL

TOP OF

DECK

60

(1524mm)

32

(813mm)

WATER
RETENTION
FLANGE
(3 SIDES)

10-1/4

(260mm)

12

(305mm)

3

(76mm)

(8) JETS

3-1/2

(89mm)

CUTOUT IN FLOOR FOR DRAIN

PUMP

FINISHED

WALL

12

(305mm)

OPT.

OPTIONAL TO 

FINISHED FLOOR 

USUALLY BETWEEN

65 & 78

(1651 & 1981mm)

C/L OF
OVERFLOW

4

(102 mm)

C/L OF
SPOUT

TILING
FLANGE

C/L OF
VALVES

C/L OF
SHOWER ARM

2-3/4

(70mm)

 4-5/8

(117mm)

1-1/2 N.P.T.M.

THREADS

3/4

(19mm)

9

(229 mm)

C/L OF

SUPPLIES

C/L OF DRAIN

SEE FITTING

SPECS FOR

DIMENSIONS

(2) AIR VALVES

ON/OFF
SWITCH

ACCESS TO PUMP/MOTOR
THROUGH REMOVABLE
FRONT ACCESS PANEL

UNDERSIDE
OF DECK

16

(406mm)

IN-LINE HEATER
REMOVABLE
BLANK

GENERAL SPECIFICATIONS FOR 2425E WHIRLPOOL

WHIRLPOOL ELECTRICAL SPECIFICATIONS

PUMP

1.6 HP, 9.7 AMPS,120V.

60 x 32 x 21-1/2 (1524 x 813 x 546mm)

115 Lbs. (52 Kg.)

574 Lbs. (258 Kg.)

55 Gal. (208 L.)

  45 Gal. (171 L.)

16-1/4 x 38-1/4 (413 x 972mm)

26-1/4 x 52-1/2 (667 x 1334mm)

15 (381mm)

 43 Lbs./Sq.Ft. (208 Kgs./Sq.m)

20.8
35.3

INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
WHIRLPOOL MIN. OPERATING VOL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT

3

)

Reviews: