ELECTRICAL DIAGRAM
READ AND FOLLOW ALL INSTRUCTIONS
BLACK
WHITE
120 VAC
GND.
WHIRLPOOL MOUNTED
AIR SWITCH OR
WALL TIMER
ELECTRICAL INSTALLATION
FOR COMBINATION SYSTEM: SEPARATE 20 AMP GFCI OUTLET
FOR WHIRLPOOL OR AIR MASSAGE: SEPARATE 15 AMP GFCI OUTLET
PUMP/MOTOR
753026-100 Rev. G
ELECTRICAL INSTALLATION INSTRUCTIONS
All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other
applicable codes.
WARNING:
When using electrical products, basic precautions should always be observed, including the following:
1.
DANGER: RISK OF ELECTRIC SHOCK
Connect only to a circuit protected by a ground-fault circuit interrupter.
2.
Grounding is required. The unit should be installed by a licensed electrician and grounded.
3.
Install to permit access for servicing.
4.
All building materials and wiring should be routed away from the pump body and heater (if equipped).
The whirlpool and air massage versions should be installed on a 120 vac, 15 amp dedicated circuit. The combination
system requires a 120 vac, 20 amp dedicated circuit. The circuit must be a three (3) wire circuit from the electrical
supply panel. A grounded neutral wire and a third wire, earth ground, are essential.
ADDING THE SAFE-T-HEATER
REQUIRES A SEPARATE 15 AMP MAXIMUM GFCI CIRCUIT.
(3)