7 3 0110 2 - 10 0   Rev.  K

10

11

ADJUSTMENTS
  

a.  Adjust water level. Water level should
     be adjusted to level indicated on tank
     by adjusting float cup.

See Step 11 for water level adjustment 
method

b.  If bowl fails to siphon, an adjustment
     may be required with the lift chain. 
     Simply remove the bead chain from
     the retainment clip and take up slack
     on the chain, and reinsert on lift rod. 
     Make sure the chain is not too taught.

12

-   3   -

CARE AND CLEANING

When cleaning your toilet, wash it with mild, soapy water, rinse thoroughly with clear water and dry with a soft cloth. Avoid detergents, 
disinfectants, or cleaning products in aerosol cans. NEVER use abrasive scouring powders or abrasive pads on your toilet seat.  Some 
bathroom chemicals and cosmetics may damage the seat's finish.

WARNING:

 Do not use in-tank cleaners. Products containing chlorine (calcium hypochlorite) can seriously damage fittings in the 

tank. This damage can cause leakage and property damage.

American Standard shall not be responsible or liable for any tank fitting damage caused by the use of cleaners containing 
chlorine (calcium hypochlorite). 

13

• Make sure water supply is 
  off. Remove valve TOP by 
  lifting arm and rotating top 
  and arm 1/8 turn 
  counterclockwise, pressing 
  down slightly on cap.

IMPORTANT: Always clear 
sand and rust from system.

• While holding a container 
over the uncapped VALVE 
to prevent splashing, turn 
water supply on and off a 
few times. Leave water 
supply off.

• 

Replace TOP by engaging 

  lugs and rotating 1/8 turn   
  clockwise. MAKE CERTAIN 
  TIP IS TURNED TO THE 
  LOCKED POSITION. VALVE 
  MAY NOT TURN ON IF TOP 
  IS NOT FULLY TURNED TO 
  THE LOCKED POSITION.

For troubleshooting information please contact:

TROUBLESHOOTING

IF FILL VALVE SHUTS OFF BUT CONTINUES TO LEAK 
SLOWLY, 

repeat Step 13.

IF FILL VALVE TURNS OFF AND ON DURING PERIODS OF 
NON-USE, 

it is a signal you are wasting water because:

• The end of the refill tube is inserted into overflow pipe, below
   water level in tank. Attach refill tube to overflow pipe using "S"
   clip provided.

• The flush valve is leaking because it's worn, dirty or
   misaligned with tank ball or flapper (replace with a new flapper).

IF FILL VALVE WON'T TURN ON OR SHUT OFF or REFILL OF 
TANK WATER IS SLOW after valve has been in use for some 
time, 

Fluidmaster Model 242 Replacement Seal may be needed.

Go to our website at www.fluidmaster.com for more solutions 
to toilet problems.

©  2001 Fluidmaster, Inc.
®  Registered trademark of Fluidmaster, Inc.

Always use quality Fluidmaster repair parts when maintaining your Fluidmaster products. Fluidmaster shall 
not be responsible or liable for any damages caused by products used with Fluidmaster valves that were 
not manufactured by Fluidmaster, Inc.

30800 Rancho Viejo Road

San Juan Capistrano, CA 92675

(949) 728-2000  (800) 631-2011

www.fluidmaster.com

!

VALVE

BODY

ADJUSTABLE
HEIGHT

WATER LEVEL 

ADJUSTMENT 

ROD

Turn on water supply. 
Submerge the FLOAT CUP 
under the water for 30 seconds. 
Adjust the water to desired level 
by turning WATER LEVEL 
ADJUSTMENT ROD and 
moving FLOAT CUP up or 
down.

LIFT ARM

FIRST

TANK
LEVER

FLUSH
VALVE

TOP

ARM

NIPPLE

Diagram 1

PARTS FOR WATER
CONNECTION
(SEE STEP 9)

CONE WASHER

FLAPPER

THREADED
SHANK

SHANK
WASHER

COUPLING NUT
(HAND TIGHT ONLY)

FILL

VALVE

FLOAT

CUP

CRITICAL LEVEL

MARK ("C.L.")

MUST BE

1" ABOVE

OVERFLOW PIPE

REFILL
TUBE

LOCK NUT

Summary of Contents for TROPIC CADET 2455

Page 1: ...ight Height Toilets Models 2455 2457 2459 2791 Triumph Cadet 3 2 piece Round Front Elongated Right Height Toilets Models 2490 2491 2492 FINISHED WALL FINISHED FLOOR SUPPLY AS REQ D 12 305mm WAX RING SEALANT 5 4 INSTALL WAX SEAL Invert toilet on floor cushion to prevent damage and install wax ring evenly around waste flange horn with tapered end of ring facing toilet Apply a thin bead of sealant ar...

Page 2: ...CAUTION DO NOT USE CONE WASHER WITH PLASTIC SUPPLY LINE These parts must be used as illustrated to insure water tight connection Use of existing coupling nut may result in water leakage Water supply tube or pipe must extend at least 1 2 inside threaded shank of valve does not apply to flanged tubing Use existing coupling nut and washer Use existing spiral cone washer Fluidmaster cone washer may no...

Page 3: ...ION VALVE MAY NOT TURN ON IF TOP IS NOT FULLY TURNED TO THE LOCKED POSITION For troubleshooting information please contact TROUBLESHOOTING IF FILL VALVE SHUTS OFF BUT CONTINUESTO LEAK SLOWLY repeat Step 13 IF FILL VALVETURNS OFF AND ON DURING PERIODS OF NON USE it is a signal you are wasting water because The end of the refill tube is inserted into overflow pipe below water level in tank Attach re...

Page 4: ... Remove cap and clean as per Step 13 a Check that refill tube is connected to water control and inserted into tank overflow without being kinked or damaged b Open supply valve fully Be sure that proper supply tube size is used c Remove obstruction Consult a plumber if necessary d Normal supply pressure must be at least 20 psi a Review Step 9 of installation procedure b Review Step 4 through 7 of i...

Reviews: