background image

Electronic Air Cleaner

ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES

IMPORTANT — This Document is customer property and is to remain with this unit.

Please return to service information pack upon completion of work.

Installation
Operation
Maintenance

Furnace Only Models

Air Handler Only Models

TFE145A9FR0

TFE215A1AH0, A9AH0

TFE175A9FR0

TFE235A1AH0, A9AH0

TFE210A9FR0

TFE260A1AH0, A9AH0

TFE245A9FR0

To reduce the risk of electric shock, this equipment has a
grounding type plug that has a third (grounding) pin. This
plug will only fit into a grounding type power outlet. If the
plug does not fit into the outlet, contact a qualified person-
nel to install the proper outlet. Do not alter the plug in any
way.

WARNING

!

This information is for use by individuals having adequate
backgrounds of electrical and mechanical experience. Any
attempt to repair a central air conditioning product may
result in personal injury and/or property damage. The
manufacturer or seller cannot be responsible for the
interpretation of this information, nor can it assume any
liability in connection with its use.

18-HE17D7-4

Contents

Installation

2

Location

2

Side Mount

3

Bottom Mount

3

Electrical

4

Ozone Reduction

5

Sequence Of Operation

5

Maintenance

5

Cleaning

6

Replacing an Ionizing Wire

6

Fuse Replacement

6

Troubleshooting

6

Power Supply

6

Cell Test

7

Airflow Monitor Test

7

Power unit Removal and Replacement

8

Summary of Contents for TFE145A9FR0

Page 1: ...oes not fit into the outlet contact a qualified person nel to install the proper outlet Do not alter the plug in any way WARNING This information is for use by individuals having adequate backgrounds...

Page 2: ...nace air handler See Figure 2 for example Select a location that meets the following 1 The face of the cell must be at a right angle to the air stream 2 Allow a minimum of 28 inches clearance in front...

Page 3: ...cabinet to the furnace Use inner mounting holes for Side Installation Figure 5 Side Installation Details Install gasket material toward inner edge Cut to length required Bottom MOUNT Furnaces or Air...

Page 4: ...ween the female polarized connector on the heater and the male polarized connector from the air handler control box See Figure 8 The polarized connectors are keyed to aid in preventing incorrect assem...

Page 5: ...CE For maximum efficiency the air cleaner cells and pre filter should be inspected and cleaned on a regular basis MAINTENANCE REPLACEMENT SCHEDULE Fan ON Continuous Fan AUTO Dusty Normal Dusty Normal...

Page 6: ...d as follows 1 Remove all pieces of broken wire Make sure supports at each end are in good condition and not bent out of shape 2 Hook the new wire onto the support at one end 3 Hold your finger agains...

Page 7: ...n a removable metal tray attached to the door If a power supply fails the complete power tray must be replaced as a unit Input voltage Furnace or Air Handler Units 120 VAC 60 Hz Air Handler Units 208...

Page 8: ...rve the following procedure 1 Disconnect power cord from the power door and remove power door from air cleaner 2 On the inside of the door remove four screws holding the power pack to the door and rem...