M968845 Rev. 1.2
Connect HOT water supply to inlet of left SHANK and COLD
water supply to right SHANK using sealant, appropriate
connectors, and COUPLING NUTS.
Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to
waste outlet.
10
Connect water supply to VALVE BODIES
(7,7a)
with
1/2" IPS FLEXIBLE SUPPLIES
(8)
or 3/8" O.D. BULL-NOSE
RISERS
(9)
. Use adjustable wrench to tighten connections.
Do not over tighten. Be careful not to kink copper supply when
bending. Use tubing cutter to cut to proper length.
TEE AND HOSE CONNECTION
NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS NOT
INCLUDED AND MUST BE PURCHASED SEPARATELY.
HOT
COLD
FLEXIBLE
SUPPLIES
1
1/2" PIPE
THREAD
3/8 COMPRESSION
CONNECTION
2
POP-UP KNOB
(1)
must be fully
down.
Fig.
A.
Thread CABLE CONNECTOR
(1)
clockwise onto DRAIN BODY
CONNECTION
(2)
and hand
tighten.
Fig.
B.
Your new POP-UP DRAIN
installation is now complete.
Fig.
C.
Note:
Tailpeice on pop-up drain
is 1-1/4” O.D.
Fig.
C.
Fig.
B.
ATTACH CABLE
CONNECTOR
8
Operate LIFT KNOB
(1)
to verify that STOPPER
(2)
opens and closes.
Note:
If STOPPER
(2)
does not open and close properly
then refer to the “troubleshooting section” of these
instructions.
CHECK OPERATION OF POP-UP
INSTALL DIVERTER KNOB
9
Fig.
C.
1-1/4” O.D.
DOWN
Fig.
A.
1
1
5
3
1
2
2
WATER SUPPLY CONNECTION
Insert SEAL
(1)
into ADAPTER
(2)
and tighten ADAPTER
(2)
to
side of TRANSFER VALVE
(3)
.
Install SEAL
(4)
into coupling nut of TEE
(5)
and tighten
connection to ADAPTER
(2).
Connect HOSE COUPLING NUTS
(6)
to Hot and Cold valve
bodies and securely tighten.
6
7
7a
6
9
Front
Push DIVERTER KNOB
(1)
onto HANDLE ADAPTER
(2)
.
Push on RING
(3)
and tighten with SCREW
(4)
.
Press on KNOB CAP
(5)
.
Note:
Screwdriver gap is for disassembling and should
point downwards.
4
2
COMPRESSION
NUT
COUPLING
NUT
OUTLINE OF BIDET
3/8 O.D.
BULL-NOSE
RISERS
CONNECT TO
WASTE OUTLET
2
3
4
5
FERRULE
3