7

   M965612 Rev. 1.8 (12/17)

C

      

FOR AC-VERSION 

(MULTI HOOK-UP); Fig. 3, 3a, 3b

1.  Remove COVERS from all CONTROL BOX (2)

2.  Remove SOLID BLACK PLUG GROMMET (5) from  

left  side of all CONTROL BOX 

(2), except from Unit 

#1.  Replace with GRAY GROMMET (9). (Supplied with     

each Faucet). 

3.  Feed SENSOR CABLES (2) through the top of  

CONTROL BOX 

(3). Connect one SENSOR CABLE (2)     

to the SOLENOID CABLE 

(7), and the other to either 

of  the two terminals at the one end of the Y-ADAPTER     

(11). Connect the 10’ EXTENSION (10a) to the other     

terminal at the same end of the Y-ADAPTER 

(11).

4.  Feed the other end of the 10 ft. EXTENSION (10b)     

through the two GRAY GROMMETS 

(6a and 6b)  

and connect to the single terminal end of the next  

unit’s   Y-ADAPTER 

(11). Place Y-ADAPTER (11) into  

CONTROL BOX 

(3).

5.  Repeat Steps above for each additional Unit, for a     

Max. of 15 Units on one AC POWER SUPPLY (7)

6.  Replace CONTROL BOX COVERS. Tighten cover      

screws firmly. 

Unit #1 Detail

Fig. 3a

2

11

10b

AC POWER SUPPLY

  2

SENSOR

CABLES

7

3

2

5

10b

10a

12

6a

6b

Fig. 3b

CAUTION: Use only American Standard supplied  
transformers and cable sets. Using non-AS supplied  
cables, or cutting, splicing or modifying any components  
will void the warranty.

Unit #2

Unit #3

Fig. 3

10 ft.

EXTENSION

CABLE

AC POWER

SUPPLY

*MAXIMUM OF 15 UNITS PER AC POWER SUPPLY.

10' MAXIMUM CABLE LENGTH BETWEEN UNITS.

OR

Unit #1

Already installed

BLACK & 

WHITE

POWER

CONNECTIONS

Summary of Contents for SERIN 2064.14 Series

Page 1: ... CRT TEAM 844 278 8326 In Canada 1 800 387 0369 In Toronto Area only 1 905 306 1093 SERIN Deck Mount Electronic Proximity Lavatory Faucet CAUTION Use only American Standard supplied transformers and cable sets Using non AS supplied cables or cutting splicing or modifying any components will void the warranty Optional 206P400 XXX 4 Deck Plate Optional 206P800 XXX 8 Deck Plate Product No s Options 1...

Page 2: ...ronic Proximity Lavatory Faucet Certified to comply with ASME A112 18 1 2014 American Standard Product No s Options Specifications Faucet Installation Electrical Installation Start up Maintenance FAQ s Troubleshooting Replacement Parts 1 2 2 3 4 6 7 8 8 9 10 Optional 206P400 XXX 4 Deck Plate Optional 206P800 XXX 8 Deck Plate NOTE TO INSTALLER Please give this manual to the customer after installat...

Page 3: ... 500mm 20 1524mm 60 413mm 16 1 4 3 8 COMP 32mm 1 1 4 DIA 125mm 4 7 8 81mm 3 3 16 MOUNTING SURFACE 249mm 9 3 4 173mm 6 11 16 100mm 3 15 16 136mm 5 3 8 177mm 7 RECOMENDED CONTROL BOX OR EQUIVALENT BY OTHERS HARD WIRED AC ONLY 10 MAX CABLE LENGTH 4 102mm SQ X 3 1 2 89mm DEEP CONTROL BOX Hubbel RACO 256 OR EQUAL BY OTHERS GENERAL DESCRIPTION Electronic faucet with proximity operation Vandal resistant ...

Page 4: ... tile or plaster walls the ANCHORS 17 and SCREWS 16 should be used 3 CONNECT SPOUT HOSETO CONTROL BOX Fig 5 1 Connect SUPPLY NUT 18 from spout hose to nipple on top of CONTROL BOX 3 Tighten with adjustable wrench to make a water tight connection Fig 3 4 CONNECT WATER SUPPLYTO CONTROL BOX AND WALL SUPPLY Fig 6 6a NOTE If using the optional Mixing Valve See Sheet M968808 for installation instruction...

Page 5: ...R 5 and terminal end is inserted first Fig 1b 4 Insert the BATTERY CONNECTOR 5a for the Standard Battery or PWRX Battery Pack through side GROMMET 6 as shown Fig 1c 5 Connect SOLENOID CABLE 7 and BATTERY CONNECTOR 5a to SENSOR CABLES 2 Place Standard Battery or PWRX Battery Pack into Housing Fig 1d 6 Replace CONTROL BOX COVER 1 Tighten cover screws firmly CAUTION Use only American Standard supplie...

Page 6: ...d install CONNECTOR LOCKING DEVICE 16 Fig 2a 5a Mount CONTROL BOX to wall Replace CONTROL BOX COVER 1 Tighten cover screws firmly 6a Plug AC POWER SUPPLY into wall outlet FOR HARDWIRE HOOK UP ONLY 2b Insert one end of the 10 EXTENSION 10a through POWER SUPPLY GROMMET 9 Fig 2b 3b Insert 10 EXTENSION 10a through side GROMMET 6 as shown Fig 2b 4b Connect 27 EXTENSION CABLES 2 to SOLENOID CABLE 7 and ...

Page 7: ...ION 10b through the two GRAY GROMMETS 6a and 6b and connect to the single terminal end of the next unit s Y ADAPTER 11 Place Y ADAPTER 11 into CONTROL BOX 3 5 Repeat Steps above for each additional Unit for a Max of 15 Units on one AC POWER SUPPLY 7 6 Replace CONTROL BOX COVERS Tighten cover screws firmly Unit 1 Detail Fig 3a 2 11 10b AC POWER SUPPLY 2 SENSOR CABLES 7 3 2 5 10b 10a 12 6a 6b Fig 3b...

Page 8: ...lows the shape of the BATTERY HOLDER 3 Prior to making power connection make sure detection zone is not obstructed Sensor is self adjusting Keep detection zone clear for 15 seconds after power is connected 4 To change PWRX BATTERY PACK 4 unplug and replace with new Power Pack 5 Reconnect BATTERY HOLDER 3 to SENSOR CABLE 5 6 Replace CONTROL BOX COVER Tighten cover screws firmly C HOWTO CLEAN FILTER...

Page 9: ...rea using a wet cloth and dry using a soft cloth CAUTION Do not scratch the sensor when cleaning Avoid using any abrasives or harsh detergents or chemicals 8 9 7 7 Fig 4 KEY 2 3 3 Fig 5 1 RINSE CLEAN FLOW REGULATOR 3 Fig 6 FAQ S Q How will I know if the battery needs to be replaced A Valve will not open and sensor will continuously blink 2 times interrupted by a pause for up to 7 days Q Why has th...

Page 10: ...NTERNAL SUPPLY STOP HEX KEY NEEDED CRITICALLY LOW BATTERY INSTALL NEW BATTERY DEAD BATTERY INSTALL NEW BATTERY REPEAT NO CHECK FOR DAMAGE TO SENSOR WIRE INSULATION REPLACE SENSOR ARE EXTERNAL SUPPLY STOPS OPEN IS INTERNAL SUPPLY STOP OPEN REPEATED DOUBLE FLASH ON SENSOR RECONNECT BATTERY TO SENSOR DOES SENSOR FLASH FOR 5 SECONDS REPLACE SOLENOID YES YES NO CHECK FOR DAMAGE TO SENSOR WIRE INSULATIO...

Reviews: