background image

In

s

t

a

ll

a

t

io

n

 I

n

s

t

r

u

c

t

io

n

s

M968567 Rev.1.2

6

Fig. 12b

3

9

1. 

Remove COVER 

(1)

 from SUPPLY STOP 

(2) 

if 

installed. 

Fig. 10.

 

2.

 Turn water supply off. 

Fig. 10.

3.

 Loosen SPUD COUPLING NUT 

(3)

. Unthread 

COUPLING NUT 

(4)

 and VACUUM BREAKER 

COUPLING NUT 

(5)

. Remove FLUSH VALVE 

(6)

.

Fig. 10.

4.

 Clean all threaded connections before installing the 

new flush valve. 

Fig. 10a.

5. 

Refer to 

Sections 5,6 and 7

 to complete the retrofit 

installation. 

Fig. 10b.

Note: In most Retrofits the wall escutcheon, supply stop, 
cover tube and vacuum breaker do not have to be replaced. 
If these items do need replacement they must be purchased 
separately or order the complete flush valve assembly from 
American Standard.

    HOW TO RETROFIT OUR VALVE;
Fig. 10

8

(Replaces Industry Standard Manual and
Electronic Valves)

CLEAN
CONNECTIONS

2

Fig. 10

Fig. 10a

Fig. 10b

1

4
5

3

6

  1. 

 Loosen SET SCREW 

(1)

 with 2.5mm Hex Wrench 

(2)

 in back of top half of FLUSH VALVE CAP 

(3)

Fig. 

12a.

2.

 Rotate CAP 

(3)

 to the right and pull off. 

Fig. 12b.

3. 

Turn CAP

 (3) 

over and remove the two SCREWS 

(4)

. Remove the BATTERY COVER 

(5)

 to expose the  

battery 

(6)

. Remove old BATTERY 

(6)

Fig. 12c.

4.

 Install the new BATTERY 

(7)

 making sure the + & - 

are facing up towards the open end of the cover.

Fig. 12d.

5. 

Replace the BATTERY COVER 

(5)

, reverse the 

above steps to assembly flush valve.   

    HOW TO CHANGE THE BATTERY;
Fig. 12

1

5

7

4

6

6

Fig. 12a

Fig. 12c

Fig. 12d

Fig. 12

OLD

BATTERY

OUT

NEW

BATTERY

IN

2

In

s

t

a

ll

a

t

io

n

 I

n

s

t

r

u

c

t

io

n

s

Summary of Contents for Selectronic Proximity Urinal Flush Valve 6063.051

Page 1: ...lve prevents clogging and reduces maintenance ONE SENSOR FITS ALL Only 1 sensor for entire Selectronic line of faucets urinals and flush valves Range can be adjusted manually or with optional remote c...

Page 2: ...RODUCT WITH SOAPS ACID POLISH ABRASIVES HARSH CLEANERS OR A CLOTH WITH A COARSE SURFACE CARE INSTRUCTIONS I n s t a l l a t i o n I n s t r u c t i o n s I n s t a l l a t i o n I n s t r u c t i o n...

Page 3: ...ents that are subject to normal wear These components should be checked on a regular basis and replaced as needed to maintain the valve s performance IMPORTANT All plumbing must be installed in accord...

Page 4: ...plied for copper pipe supply line Fig 3 1 Measure the distance A from the finished wall to the center of the inlet spud on the fixture 2 Cut the supply pipe 1 1 4 A B C shorter then the measurement ta...

Page 5: ...Fig 6 4 1 4 Fig 7a Fig 7c Fig 7d Fig 7 3 The UNIT is shipped with the inlet flange on the right side If needed the orientation can be reversed by following the steps below 1 Loosen SET SCREW 1 with 2...

Page 6: ...imately 3 seconds 4 Adjust SUPPLY STOP 3 after each flush until the stated flush volume is achieved no splashing occurs and the fixture is properly cleansed 5 When adjustment is complete replace COVER...

Page 7: ...or order the complete flush valve assembly from American Standard HOW TO RETROFIT OUR VALVE Fig 10 8 Replaces Industry Standard Manual and Electronic Valves CLEAN CONNECTIONS 2 Fig 10 Fig 10a Fig 10b...

Page 8: ...ecure the CAP 3 at this time Note You have 5 seconds after connecting cable to enter program code 5 While the SENSOR CONTROL LED 6 is blinking slowly place your hand 1 to 2 in 30 50mm in front of the...

Page 9: ...FIRST 5 SECONDS NO REPLACE SOLENOID KIT RETRY AUTOMATIC FLUSH WAS IT SUCCESSFUL YES 1 COVER SENSOR FOR 10 SECONDS 2 UNCOVER SENSOR FOR 10 SECONDS REPLACE BATTERY SEE STEP 10 page 6 in manual MANUAL VA...

Page 10: ...JUSTABLE TAILPIECE M952261 0020A 3 4 INLET PIPE ASSEMBLY M952263 0020A 3 4 VACUUM BREAKER ASSEMBLY M952262 0020A 3 4 SPUD ASSEMBLY SELECTRONIC PROXIMITY URINAL FLUSH VALVE 0 5 1 0 GPF A955058 0020A 3...