background image

In

s

t

a

ll

a

t

io

n

 I

n

s

t

r

u

c

t

io

n

s

1.

 Adjust temperature by inserting a 4mm Hex Wrench 

into hex opening in the side of enclosure. Fig. 6.

2.

 To decrease temperature, rotate up. (clock-wise)

3.

 To increase temperature, rotate down. (counter- 

clockwise)

    TO ADJUST TEMPERATURE;
Fig. 6

4

1.

 Turn off water supply.

2.

 Remove MIXING VALVE ENCLOSURE COVER.

3.

 Disconnect MIXING VALVE (1) from SELECTRONIC 

ENCLOSURE (2). Fig. 7.

4.

 Pull MIXING VALVE (1) out from ENCLOSURE (5). 

If SUPPLY HOSES (3) are not long enough to gain 
access to TEMPERATURE CALIBRATION UNIT (6) 
&THERMOSTATIC CARTRIDGE (4) disconnect 
SUPPLY HOSES (3) from wall valves. Fig. 7a.

5.

 Rotate the BLACK CLAMP (7) with your finger and 

pull off the TEMPERATURE CALIBRATION UNIT (6). 
Fig 7b, 7c. 

6.

 Use a adjustable wrench to unthread 

THERMOSTATIC CARTRIDGE (4) from housing. Fig. 7d.
  

7.

 Remove THERMOSTATIC CARTRIDGE (4). Fig. 7e.

8.

 Rinse clean any debris from SCREENS (8) and 

inspect O-RINGS (9) for damage. Replace O-RINGS (9) 
if any damage is found. Fig. 7f.

9.

 Reverse above steps and reassemble MIXING 

VALVE (1).  Assemble MIXING VALVE (1) to 
SELECTRONIC ENCLOSURE (2).

10.

 Assembly ENCLOSURE COVER and tighten 

securley.

    TO SERVICE CARTRIDGE; Fig; 7

5

 3

Fig. 6

Fig. 7

TO INCREASE
TEMPERATURE

TO DECREASE

TEMPERATURE

4mm HEX
WRENCH

Fig. 7b

Fig. 7f

Fig. 7d

Fig. 7d

Fig. 7a

Fig. 7a

Fig. 7c

Fig. 7e

Fig. 7e

1

6

7

4

4

4

8

9

1

3

2

6, 4

5

SERVICE

ADJUST TEMPERATURE

In

s

t

a

ll

a

t

io

n

 I

n

s

t

r

u

c

t

io

n

s

Reviews: