background image

4

3

5

24"

(610mm)

2
1

2

MAKE WATER SUPPLY CONNECTIONS

4

4a

TEST INSTALLED FAUCET

3

CONNECT SPRAY HOSE & INSTALL WEIGHTS

Move HANDLE 

(1)

 into "off"

position.

With HANDLE 

(1)

 in "off" position,

unthread SPRAY 

(3)

 from HOSE 

(2)

.

Turn on water supplies.

Operate handle back to front, in COLD

and HOT positions, to flush water lines

thoroughly.

Replace SPRAY 

(3)

 onto HOSE 

(2)

.

Push the SPRAY HOSE END 

(1)

 into the HOSE CONNECTOR 

(2)

until it snaps into place.

With hand spray seated in spout, install WEIGHT 

(3)

onto HOSE 

(4) 

24 inches from the underside of the sink deck 

and secure with SCREW 

(5)

.

Check connections for leaks.

(See Section 5)

Turn off hot and cold water supplies before beginning.
Connect FLEXIBLE SUPPLIES 

(1, 2)

 directly

to wall supplies. Connection on fitting

supplies are 3/8" compression. Connect

left supply (Marked with a Red Stripe) to Hot

and right supply (Marked with Blue Stripe) to 

Cold wall supply. Use adjustable wrench to 

tighten connections. Do not over tighten.

Faucet supplies are 21" long from faucet base.

Note: If additional supply length is

required, installer must purchase

additional parts separately.

Important: If SUPPLY HOSES (1, 2) are

too long, loop as illustrated to avoid kinking.

1

REMOVE

M 9 6 5 4 5 5   Rev.  1. 2

3

3

4

2

1

2

COLD

HOT

SPRAY OPERATION

With FAUCET on pull down SPRAY 

(3). 

Check for

leaks. Make sure SPRAY 

(3)

 fully retracks and is

seated in the SPOUT HOLDER 

(4)

.

Summary of Contents for PORTSMOUTH 4285.410

Page 1: ...illips Screwdriver RECOMMENDED TOOLS Regular Screwdriver Insert HOSES 2 through RUBBER WASHER 4 BRASS WASHER 5 and threaded LOCKNUT 6 Turn off water at main supply CAUTION PORTSMOUTH M965455 Rev 1 2 B A SINK OR MOUNTING SURFACE 4 5 8 7 6 A Installation with ESCUTCHEON 1 Apply a bead of putty to bottom edge of ESCUTCHEON with PUTTY PLATE 1 Make certain the SEAL 9 is properly seated in recess of fau...

Page 2: ...ons for leaks See Section 5 Turn off hot and cold water supplies before beginning Connect FLEXIBLE SUPPLIES 1 2 directly to wall supplies Connection on fitting supplies are 3 8 compression Connect left supply Marked with a Red Stripe to Hot and right supply Marked with Blue Stripe to Cold wall supply Use adjustable wrench to tighten connections Do not over tighten Faucet supplies are 21 long from ...

Page 3: ... off to on Do not apply excessive force Remove INDEX BUTTON 1 loosen HANDLE SCREW 2 and remove HANDLE 3 Unthread the ESCUTCHEON CAP 4 Unthread three MOUNTING SCREWS 5 Lift CARTRIDGE 6 off MANIFOLD 7 Replace ESCUTCHEON CAP 4 HANDLE 3 tighten HANDLE SCREW 1 and install INDEX BUTTON 2 Clean MANIFOLD 7 and CARTRIDGE 6 ports Place CARTRIDGE 6 onto MANIFOLD 7 and tighten MOUNTING SCREWS 5 alternately CA...

Page 4: ...69 TORONTO 1 905 306 1093 Weekdays 8 00 a m to 7 00 p m EST IN MEXICO 01 800 839 1200 P r o d u c t n a m e s l i s t e d h e r e i n a r e t r a d e m a r k s o f A m e r i c a n S t a n d a r d I n c A S A m e r i c a I n c 2 0 1 2 HOT LINE FOR HELP M964396 YYY0A HANDLE KIT M964397 0070A BUTTON AND SCREW KIT M907315 YYY0A ESCUTCHEON CAP M951483 0070A CARTRIDGE M918511 0070A CARTRIDGE SCREWS PORT...

Reviews: