INSTALLATION INSTRUCTIONS
The manufacturer’s warranty does not cover any damage or defect caused by installation, attachment or use of any
type of energy saving or other unapproved devices (other than those authorized by the manufacturer) into, onto or
in conjunction with the water heater. The use of unauthorized energy saving devices may shorten the life of the
water heater and may endanger life and property. The manufacturer disclaims any responsibility for such loss or
injury resulting from the use of such unauthorized devices. If local codes require external application of insulation
blanket kits, the manufacturer’s instructions included with the kit must be carefully followed. Application of any
external insulation, blankets or water pipe insulation to this water heater will require careful attention to the
following:
Do not cover access panels to the heating elements.
Do not cover the electrical junction box of the water heater.
Do not cover the operating or warning labels attached to the water heater or attempt to relocate them
on
the
exterior of the insulation blanke
t
.
Do not block the air inlet outlets below and on the top covers.
Wind ring is a selectable accessory. If there is a wind ring, it can be selected to connect the air pipe.
(Refer to the following figure.)
To ensure fluent draining of condensate water from evaporator, please install the main unit on a level floor.
Otherwise, please ensure that the drain vent is at the lowest possible location. Recommended angle of unit to the
ground should no more than 2°.
D
Drain
Drain
Drain
19
2º
2º