7302187-100
BACK-TO-BACK INSTALLATION
Recommended fitting type for
back-to-back installations.
Depending upon your plumbing and venting conditions, the flow from the toilet in a back-to-back
installation may create a vacuum on the system and draw water from the opposing bowl. The
National Standards Plumbing Code prohibits the use of a cross fitting for drainage as throw over
is possible. The code does approve a directional "Y" style fitting with proper venting to direct the
water downward and away from the other toilet.
Press firmly.
Wax Ring
1
2
Turn Off Water Supply
Flush to remove
water from tank;
sponge remaining
water from
bowl before
removing toilet.
Clean Flange
Before You Start:
If Removing An Existing Toilet
!
Caution: If leaving floor flange
open for more than 1-2 hours,
cover flange to prevent escaping
sewer gases.
ROUGHING-IN DIMENSIONS:
NOTE:
Distance from wall to closet flange
centerline must be as listed:
3-1/8"
(80 mm)
3-1/8" (80 mm)
1"
±
1/4"
(25 mm
±6mm
)
30-1/4"
(768 mm)
12"
(305 mm)
9"
(229 mm)
18-1/2"
(470 mm)
16-1/2"
(419 mm)
7-5/8"
(194 mm)
15-1/16"
(383 mm)
30-13/16"
(782 mm)
19-3/4"
(501 mm)
14"
(356 mm)
11-5/8"
(296 mm)
FINISHED WALL
FINISHED
FLOOR
C/L OF OUTLET
C/L OF SEAT POST HOLES
140mm (5-1/2" CENTERS)
SUPPLY
AS
REQ'D
*10"
(254mm)
*6"
(152mm)
Installation video can be found at:
http://www.americanstandard-us.com/vormaxtoilet