2
1
4
1
SERVICE
10
TEST INSTALLED FITTING
With HANDLES
(1)
in OFF position, turn on WATER
SUPPLIES
(2)
and check all connections for leaks.
Remove AERATOR
(3)
.
Operate both HANDLES
(1)
to flush water lines thoroughly.
Replace AERATOR
(3)
.
5
2
CHECK DRAIN CONNECTIONS
Operate POP-UP KNOB
(4)
and fill lavatory with water.
Check that DRAIN STOPPER
(5)
makes a good seal
and retains water in SINK. If DRAIN STOPPER
(5)
does not seal properly, please refer to Troubleshooting
section in these instructions.
Release POP-UP KNOB
(4)
down and check all drain
connections and "P" trap for leaks. Tighten
if necessary.
90˚
6
5
12
11
American Standard’s EverClean finish will wipe clean with a soft, dry cloth. A soft cloth with clean
water may also be used, if desired. No additional cleaning products are required.
DO NOT USE: Soaps, acid, polish, abrasives, harsh cleaners, or a cloth with a coarse surface.
EverClean™ Finish Care Instructions
“P” TRAP
WASTE
OUTLET
3
If spout drips, operate handles several times
from OFF to ON position. Do not force - handles
turn only 90˚.
T
o change direction of handle rotation, proceed as follows:
T
urn valve to OFF position.
Remove IINDEX
(1)
and HANDLE SCREW
(2)
.
Pull HANDLE
(3)
off.
Remove ADAPTER
(4)
and SPRING CLIP
(5)
.
Lift STOP WASHER
(6)
, turn 90˚ and replace.
Replace SPRING CLIP
(5)
.
Replace ADAPTER
(4)
, HANDLE
(2)
, SCREW
(2)
,
and INDEX
(1)
.
4
2
1
3
U S 6 0 4 0 2 R e v. 1 . 1
4