background image

2

1

4

1

SERVICE

10

TEST INSTALLED FITTING

With HANDLES 

(1)

 in OFF position, turn on WATER

SUPPLIES

(2)

 and check all connections for leaks.

Remove AERATOR 

(3)

.

Operate both HANDLES 

(1)

 to flush water lines thoroughly.

Replace AERATOR 

(3)

.

5

2

CHECK DRAIN CONNECTIONS

Operate POP-UP KNOB 

(4)

 and fill lavatory with water.

Check that DRAIN STOPPER 

(5)

 makes a good seal

and retains water in SINK. If DRAIN STOPPER 

(5)

does not seal properly, please refer to Troubleshooting
section in these instructions.

Release POP-UP KNOB 

(4)

 down and check all drain

connections and "P" trap for leaks.     Tighten
if necessary.

90˚

6

5

12

11

American Standard’s EverClean finish will wipe clean with a soft, dry cloth. A soft cloth with clean
water may also be used, if desired. No additional cleaning products are required.

DO NOT USE: Soaps, acid, polish, abrasives, harsh cleaners, or a cloth with a coarse surface.

EverClean™ Finish Care Instructions

“P” TRAP

WASTE

OUTLET

3

If spout drips, operate handles several times
from OFF to ON position. Do not force - handles
turn only 90˚.

T

o change direction of handle rotation, proceed as follows:

T

urn valve to OFF position.

Remove IINDEX 

(1)

and HANDLE SCREW 

(2)

.

Pull HANDLE 

(3)

 off.

Remove ADAPTER 

(4)

 and SPRING CLIP 

(5)

.

Lift STOP WASHER 

(6)

, turn 90˚ and replace.

Replace SPRING CLIP 

(5)

.

Replace ADAPTER 

(4)

, HANDLE 

(2)

, SCREW 

(2)

,

and INDEX 

(1)

.

4

2

1

3

U S 6 0 4 0 2   R e v. 1 . 1

4

Reviews: