American Standard FLUENT 7186.801 Installation Instructions Manual Download Page 5

M965622 Rev. 1.2 (12/17)

Fig.

 

F.

5

Speed Connect

®

 Drain

Troubleshooting Guide

Disconnect the Cable from the Drain by threading the Cable Connector 

(1)

 counter-clockwise. 

Fig.

 

A.

Look at the area on the Drain Body where the Cable was attached and locate the component labeled
as “Cam”  and “Cam Cap” in the illustration. 

Fig.

 

B.

Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain. 

Fig.

 

D.

Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. 

Fig.

 

E.

The Stopper can now be removed by lifting it out of the Drain. 

Fig.

 

F.

CAM

CAM CAP

If sink does not hold water even though Stopper is in the “down” position:

     • Follow CABLE ADJUSTMENT PROCEDURE.

If Stopper does not raise up fully or sink drains too slowly:

     • Follow CABLE ADJUSTMENT PROCEDURE.

If you need to remove the Stopper:

     • Follow STOPPER REMOVAL PROCEDURE.

If you would like the ability to remove your Stopper simply by lifting it out of the drain:
     •

 Follow STOPPER INSTALLATION PROCEDURE for 

“Unlocked” mode

.

 

                                                                          

Fig.

 

B.

Fig.

 

A.

REMOVE
CAM

Fig.

 

E.

STOPPER REMOVAL PROCEDURE

2

1

RE-ATTACH

DISCONNECT

Fig.

 

D.

REMOVE
CAM CAP

STOPPER

Fig.

 

C.

DOWN

CABLE ADJUSTMENT PROCEDURE

Disconnect the Cable from the Drain by threading the CABLE CONNECTOR 

(1)

 counter-clockwise. 

Fig.

 

A.

Look at the area on the Drain Body where the Cable was attached and locate the component labeled as
“Cam” in the illustration. 

Fig.

 

B.

Use a small flat head screwdriver to fully rotate the Cam in the clockwise direction. At this point the
Stopper should be in the UP position. 

Fig.

 

B, C.

 

Make sure the LIFT KNOB 

(3)

 it is fully down. 

Fig.

 

C.

Re-attach the CABLE CONNECTOR 

(1)

 to the CABLE ATTACHMENT POINT 

(2)

 by threading the CABLE

CONNECTOR 

(1)

 clockwise onto the CABLE ATTACHMENT POINT 

(2)

 and hand-tighten. 

Fig.

 

A.

3

Summary of Contents for FLUENT 7186.801

Page 1: ...L WASHERS 12 are properly seated in each HANDLE BASE 13 Assemble RUBBER WASHER 9 and thread LOCKNUT 8 onto each SIDE VALVE SHANK 10 from underside of sink or mounting surface Align and center SIDE VAL...

Page 2: ...B 2 4 3 TIGHTEN LOCKNUT 1 REMOVE FLANGE Remove CLEAR PLASTIC COVER 1 Remove CARDBOARD SPACER 2 from under DRAIN POP UP 3 2 2 3 3 1 1 INSTALL DRAIN FROM BELOW FIXTURE 5 From under side of SINK install...

Page 3: ...waste outlet Connect FLEXIBLE SUPPLIES 1 2 directly to wall supplies Connection on fitting supplies is 3 8 compression Connect FLEXIBLE SUPPLY 1 Marked with a Red Band to the Left wall supppy and FLEX...

Page 4: ...OTH DO NOT DO NOT CLEAN THE PRODUCT WITH SOAPS ACID POLISH ABRASIVES HARSH CLEANERS OR A CLOTH WITH A COARSE SURFACE CARE INSTRUCTIONS 90 90 4 HOT 13 SERVICE To change direction of handle 1 1 COLD 2 2...

Page 5: ...USTMENT PROCEDURE If you need to remove the Stopper Follow STOPPER REMOVAL PROCEDURE If you would like the ability to remove your Stopper simply by lifting it out of the drain Follow STOPPER INSTALLAT...

Page 6: ...and not be removable Unlocked Mode Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig H To install the stopper in Unlocked mode insert the...

Page 7: ...2 YYY0A HANDLE BASE M904924 0070A CARTRIDGE NUT M964005 0070A CARTRIDGE Wide Spread Lavatory Faucet with Speed Connect Drain M964923 YYY0A LIFT ROD AND KNOB M904521 0070A T CONNECTOR M964479 0070A AER...