background image

M965263 REV. 1.9 (8/17)

3mm
HEX WRENCH

FRICTION WASHER

Pull out INDEX BUTTON 

(1).

 Loosen HANDLE SCREW 

(2) 

with 2.5mm Hex Wrench, then

pull HANDLE  

(3) 

off.

Unthread ESCUTCHEON CAP 

(4)

. Unthread the CARTRIDGE NUT 

(5)

.

Remove CARTRIDGE 

(6)

. Clean inlets of CARTRIDGE 

(6) 

and MANIFOLD 

(7)

.

Reassemble CARTRIDGE 

(6)

. Replace CARTRIDGE NUT 

(5)

, CAP 

(4)

 and HANDLE assembly, check flow.

SERVICE

Clogged CARTRIDGE outlets or inlets may cause reduced
flow. 

To clean, first turn off water supply then:

2

11

3

1

4

5

6

7

If SPOUT (10) leaks at swivel point the O-RINGS (9) need
to be replaced. To remove SPOUT (10)

:

Loosen the SPOUT SET SCREW 

(8)

 with a 3mm Hex wrench. (Supplied)

Rotate the SPOUT 

(10)

 side to side while pulling upward to remove SPOUT 

(10)

 from faucet body.

Replace the defective parts and grease O-RINGS 

(9) 

with plumber’s grease. Push SPOUT 

(10)

 back into position.

Tighten SET SCREW 

(8)

Check that SPOUT 

(10)

 rotates freely and does not leak at the swivel point. 

REMOVE

INSTALL

10

9

8

CLEAN

AERATOR 

(11)

 and HOSE FILTER SCREENS 

(12)

 may accumulate debris causing distorted or reduced water flow.

Remove AERATOR 

(11) 

and/or water supplies and rinse clean.

12