background image

- 3 -

    

M965966 Rev. 1.0 (12/18)

6

CARE INSTRUCTIONS:

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.

4

•  By restricting HANDLE rotation and limiting the amount of hot water 

allowed to mix with the cold, the HOT LIMIT SAFETY STOP 

(1)

  

reduces risk of accidental scalding. To set the maximum hot water  
temperature of your faucet valve, adjust the setting on the HOT LIMIT 
SAFETY STOP 

(1)

.

•  Turn CARTRIDGE STEM 

(2)

 to the OFF position (coldest setting) before 

making adjustment to HOT LIMIT STOP 

(1)

.  Pull forward and rotate 

counterclockwise one number to limit hot water temperature.  
Use NUMBERS 

(5)

 on CARTRIDGE 

(4)

 on HOT LIMIT STOP 

(1)  

for indication.

ADJUST HOT LIMIT STOP

COLDER

(Larger Numbers)

1 2 3 4 5 6 7 8 9 10

HOTTER

(Smaller Numbers)

1 2 3 4 5 6 7 8 9 10

3

4

1

5

2

5

VALVE LEAKS WHEN SHUT OFF

•  Remove CARTRIDGE, see STEP 1 and STEP 2 and REVERSE process.
•  Clean SEALS on the side of CARTRIDGE. Clean inside sealing surface of VALVE BODY.
•  Re-assemble CARTRIDGE. Install trim. Turn on water supply and check for leaks.

REPLACING CARTRIDGE

•  To remove CARTRIDGE

 (1)

, install split WASHER 

(3) 

between the ridge on the cartridge and the bonnet nut

 

(only 

supplied with replacement cartridge) as shown.

•     Proceed  to  unthread  BONNET NUT

 (2)

 counter clockwise. 

Note:

 CARTRIDGE

 (1)

 should be pulling out while unthreading BONNET NUT 

(2)

.

•  

Upon removal of the old Cartridge, install a new cartridge and secure it with 

BONNET NUT

  

(Hand tighten).

BACK TO BACK INSTALLATION

• 

NOTE:

 Must purchase specialized back to back cartridge. (Part number M970640-0070A)

• Remove CARTRIDGE 

(1) 

as detailed in steps above. 

• Install back to back cartridge.

•  Remove HANDLE (see step 3 and reverse).
•  Remove ESCUTCHEON and CARTRIDGE CAP (see step 1 and reverse).

SERVICE
TO GAIN ACCESS TO VALVE FOR SERVICING

CAUTION

Turn off hot and cold water 

supplies before beginning.

Figure 1.

1

3

2

Summary of Contents for Edgemere TU018500

Page 1: ...LL 18 457 mm OPTIONAL 4 1 8 108 mm TOP OF TUB RIM 5 1 8 130 mm Ref 4 102 mm 1 2 NPT 2 3 4 MAX 69 mm 1 3 4 MIN 45 mm ROUGHING IN DIMENSIONS To assure proper positioning in relation to wall Note roughing in dimensions CARTRIDGE INSTALLATION 1 1 1 2 6 5 3 4 UP UP To ensure that your installation proceeds smoothly please read these instructions carefully before you begin For use with shower heads rate...

Page 2: ...shower elbow Thread SHOWER HEAD 4 onto SHOWER ARM 3 CAUTION Protect finish on SHOWER HEAD and ARM when installing CAUTION Protect finish on SHOWER HEAD and TUB SPOUT when installing C H OFF PIPE PLUG PIPE CAP 4 3 2 SHR ELBOW TUB FILLER NIPPLE 1 1 2 REF 2 5 MM HEX WRENCH 1 5 C H OFF 1 2 5MM HEX WRENCH 3 2 STANDARD WALL INSTALLATION U P 4 2 U P 1 1 2 U P 1 PLASTER GUARD Figure 2 Figure 1 Figure 1a 1...

Page 3: ... 3 4 5 6 7 8 9 10 3 4 1 5 2 5 VALVE LEAKS WHEN SHUT OFF Remove CARTRIDGE see STEP 1 and STEP 2 and REVERSE process Clean SEALS on the side of CARTRIDGE Clean inside sealing surface of VALVE BODY Re assemble CARTRIDGE Install trim Turn on water supply and check for leaks REPLACING CARTRIDGE To remove CARTRIDGE 1 install split WASHER 3 between the ridge on the cartridge and the bonnet nut only suppl...

Page 4: ...ative Plate M970145 002250A Shower Head 2 5 gpm M970145 002180A Shower Head 1 8 gpm M970448 YYY0A Escutcheon Screws M907051 YYY0A Cover M970057 YYY0A Lever Handle Kit M970114 YYY0A Set Screw Button Kit NOTE TO AVOID SHOWER RISE OR OTHER RELATED ISSUES DO NOT USE PEX CONNECTIONS ON ANY OF THE OUTLETS M954805 YYY0A Deep Rough in Kit PURCHASE SEPARATELY PURCHASE SEPARATELY M970640 0070A Back to Back ...

Reviews: