Place the tub on a finished, level floor in the 

desired location.

Using an erasable pencil or marker, trace the outline of 

the base of the tub on the floor. (See Fig. 1)

1

Using the adjustable feet on the underside of the tub, ensure 

that the tub is level. 

Ensure that there is a gap between the tub base and the floor.  
Gap shall not exceed 1/8" [3 mm]. (See Fig. 2)

2

3

The tail piece assembly, consisting of a flanged tail piece, drain tail piece 
gasket and slip-joint nut used to connect the the tub drain to the drain/waste 
outlet, is included with this product. 

The 1-1/2" diameter tail piece is compatible with drain provided.  (See Fig. 4)

Slide the slip-joint nut over tail piece towards the flanged end as shown.

Slide the P-trap slip-joint nut and seal over the tail piece as shown.

Insert the tail piece into the P-trap.

  

REMOVE THE TUB 

Using the traced outline for reference, confirm that the 
drain/waste outlet in the floor will align with the tub drain outlet.

  

(Tub drain outlet will be located in the center of the traced 
outline. See Fig. 3)

Note: The drain/waste outlet must be installed in 

accordance with all local building codes.

  

All drain connections must be made using an 

access created beneath the tub. 

4

 DRAIN TAIL PIECE GASKET

SLIP-JOINT NUT

TAIL PIECE

P-TRAP

FIG. 4

1/8" MAX

  (3mm)

FIG. 1

FIG. 2

FIG. 3

(INCLUDED)

DRAIN

FLOOR CUTOUT

TRACED 

OUTLINE

 THREADED PORTION

OF DRAIN BODY

FINISHED FLOOR

TAIL PIECE

ASSEMBLY

  For MODEL# 

D12536-004

5-3/4" [145 mm]

For MODEL# 

D12536-014

4-7/8" [124 mm]

   FINISHED

     FLOOR

INSTALLING THE 1-1/2" DIAMETER TAIL PIECE ASSEMBLY INTO P-TRAP 

The flange of the tail piece should be approximately 5-3/4" [145 mm] or 
4-7/8" [124 mm] depending on model, above the finished floor when fully 
inserted into the P-trap.  

The tail piece can be cut if necessary.

  

SLIP-JOINT NUT

P-TRAP

& SEAL

(PROVIDED BY 

   INSTALLER)

(PROVIDED BY 

   INSTALLER)

 754988-100 REV. B (5/15)

Summary of Contents for DXV LYNDON D12536-004

Page 1: ...INSTALLER Please deliver this manual to homeowner CAUTION PRODUCT IS FRAGILE TO AVOID BREAKAGE AND POSSIBLE INJURY HANDLE WITH CARE Thank you for selecting DXV by American Standard To ensure this pro...

Page 2: ...le of Contents Page 2 Safety Instructions Notice Page 3 General Installation Information Page 4 Tub Specifications Page 5 Roughing in References Page 6 Freestanding Tubs Page 7 Post Installation Instr...

Page 3: ...jury Do not overfill bathtub before entering Entering tub when filled more than 2 3 can cause overflow and slippery conditions Exercise caution when entering and exiting WARNING No food or alcoholic b...

Page 4: ...OR INDOOR USE ONLY TEST PROCEDURES 1 Place the tub on a flat surface such as a driveway 2 Seal the drain 3 Fill tub and allow tub to stand for five minutes Examine all fittings carefully for leaks NOT...

Page 5: ...te shown below Most of the procedures require the use of common tools and materials which are available from hardware and plumbing supply stores It is essential that the tools and materials be on hand...

Page 6: ...p REMOVE THE TUB Using the traced outline for reference confirm that the drain waste outlet in the floor will align with the tub drain outlet Tub drain outlet will be located in the center of the trac...

Page 7: ...equire access from beneath the tub 754988 100 REV B 5 15 No fixtures can be mounted on the tub deck of freestanding tubs Floor or wall mounted fixtures are required Wall Mounted The position of the tu...

Page 8: ...formation may also be obtained by calling the following toll free number 800 227 2734 www DXV com In Canada DXV by American Standard 5900 Avebury Road Mississauga Ontario L5R 3M3 Canada Toll Free 1 80...

Reviews: