![American Standard Doral Classic Champion 2076 Installation Instructions Manual Download Page 4](http://html1.mh-extra.com/html/american-standard/doral-classic-champion-2076/doral-classic-champion-2076_installation-instructions-manual_2926749004.webp)
7 3 0 5 2 9 - 1 0 0 R e v . M
- 4 -
10
9b
ADJUSTMENTS
a. Adjust water level. Water level should be adjusted to level indicated in tank by adjusting float
cup. See Step 11 for water level adjustment method.
IMPORTANT:
b. If
bowl fails to siphon, an adjustment may be required with the lift chain. Simply remove the bead
chain from the retainment clip (see Fig. 10A) and take up slack on the chain, and reinsert on lift
rod. Make sure the chain is not too taught.
With correct washers in
place (see Step 9a), tighten
COUPLING NUT 1/4 turn
beyond hand tight.
DO NOT OVERTIGHTEN.
TANK
LEVER
REFILL
TUBE
LINK
TOP
ARM
NIPPLE
Diagram 1
PARTS FOR WATER
CONNECTION
(SEE STEP 9)
CONE WASHER
VALVE
BODY
WATER LEVEL
ADJUSTMENT
CLIP
THREADED
SHANK
SHANK
WASHER
COUPLING NUT
(HAND TIGHT ONLY)
FILL
VALVE
FLOAT
CUP
CRITICAL LEVEL
MARK ("C.L.")
MUST BE
1" ABOVE
OVERFLOW PIPE
ADJUSTABLE
HEIGHT
LOCK NUT
Fig. 10A
11
Turn on water supply.
Adjust water to water
level specified in the tank
by squeezing water level
adjustment clip and
moving FLOAT CUP up
or down along stainless
steel link.
SEAL REPLACEMENT
:
1. Disconnect
Chain.
2. Lift float up and remove flush valve seal by pulling seal
out of groove and sliding up over float.
3. Reverse procedure to install new seal.
TROUBLE SHOOTING FLUSH VALVE
:
NOTE
: DO NOT ADD ANY FOREIGN MATERIALS
TO THE SEALING SURFACE.
13
13a
REFILL TUBE REPLACEMENT
:
12
When cleaning your toilet, wash it with mild, soapy water, rinse
thoroughly with clear water and dry with a soft cloth.
WARNING:
Do not use in-tank cleaners. These products can
seriously damage fittings in the tank. This damage can cause leakage
and property damage.
American Standard shall not be responsible or liable for any
damage caused by the use of in-tank cleaners.
!
CARE AND CLEANING
Locate bottom portion of
hose clip between the ribs (2)
on bottom of funnel inlet.
Note: Rotate funnel to position
ribs at rear of the tank.
FLOAT
FLUSH
VALVE
SEAL