- 3 -
1
2
3
4
Figure B.
Figure C.
Figure A.
SPLINE
LEVEL
3/8" HEX
WRENCH
Figure D.
5
2
3
8
6
7
3
4
INSTALL FAUCET MOUNTING ADAPTER
INSTALL POT FILLER
• Apply
Sealing Tape
to the threads of the
Supply Nipple
.
Figure A.
• Thread the MOUNTING ADAPTER
(1)
onto the Supply
Nipple until tight against the the finished wall. Use a 3/8
Hex Wrench.
Figure B.
• Install the ESCUTCHEON
(1)
onto the pot filler body. Align the
POT FILLER
(2)
and install it onto the spline of the MOUNTING
ADAPTER
(3)
. Be carefull not to damage the O-RING SEALS
(4)
on the MOUNTING ADAPTER
(3)
.
Figure A.
• Use a level as shown to help align the pot filler.
Note: If the pot
filler cannot be leveled, remove the pot filler from the mounting
adapter. With the 3/8 hex wrench rotate the mounting adapter
until a level position is acheived. Figure A.
• When the MOUNTING ADAPTER
(3)
is properly positioned, drill
four pilot holes. Secure the MOUNTING ADAPTER
(3)
with the four
MOUNTING SCREW
(5)
provided.
Figure B.
• Reinstall the POT FILLER
(2)
onto the MOUNTING ADAPTER
(3)
,
check for level.
Figure C.
• If the POT FILLER
(2)
is level, tighten the two SET SCREWS
(6)
with the small HEX WRENCH
(7)
provided. Push the ESCUTCHEON
(1)
flush against the finshed wall.
Figure D.
• Turn on the water supply. Check for leaks and proper operation.
M985014 (3/19)
WALL BOARD
SEALING TAPE
FINISHED WALL
Figure A.
SUPPLY NIPPLE
3/8" HEX WRENCH
Figure B.
SUPPLY NIPPLE
1