background image

M968955 REV. 1.2

5

TEST INSTALLED FAUCET

Move HANDLE down into "off" position and remove AERATOR.

Turn on water supplies and check connections for leaks

.

Operate HANDLE up and down, left and right to flush water

lines thoroughly.

For faucet with spray, direct SPRAY HEAD into sink and

activate SPRAY. Check hose connections for leaks.

Move HANDLE down to "off" position and replace AERATOR.

A E R AT O R

Spout leakage

. If fitting leaks above or below SPOUT HUB remove SPOUT as follows

and check SPOUT O-RINGS and SPACER O-RINGS.

Remove HANDLE BUTTON 

(2)

 and loosen SET SCREW 

(1)

. Pull HANDLE 

(3)

 off valve stem.

Remove CAP 

(4)

 and and RETAINER 

(5)

. Loosen CARTRIDGE SCREWS 

(6)

 and

remove CARTRIDGE 

(7)

.

Pull off SPACER 

(8)

 and O-RINGS 

(9)

.

Remove SPOUT 

(12)

 by pulling up gently while moving SPOUT 

(12)

 side to side.

Check both SPOUT O-RINGS 

(11)

. Replace if necessary.

On models with SPRAYS, DIVERTER 

(10)

 can be cleaned by pulling

DIVERTER 

(10)

 out of the MANIFOLD 

(13)

. Clean DIVERTER 

(10)

 and

MANIFOLD 

(13)

. Push DIVERTER 

(10)

 back into MANIFOLD 

(10)

.

Reverse procedure to reinstall SPOUT, CARTRIDGE and HANDLE.

Remove PLUG BUTTON 

(2)

, loosen HANDLE SCREW 

(1)

 and remove HANDLE 

(3)

.

Remove ESCUTCHEON CAP 

(4)

. unscrew the three CARTRIDGE SCREWS 

(6)

.

Clean inlets of CARTRIDGE 

(7)

 and MANIFOLD 

(13)

.

Reassemble CARTRIDGE 

(7)

, alternately tightening SCREWS 

(6)

. Replace CAP 

(4)

 and HANDLE 

(3)

. Check flow.

SERVICE

6

Clogged CARTRIDGE outlets or inlets may cause reduced flow.

To clean, first turn off water supply then:

Reduced flow

. If the flow gradually reduces over a number of months, the AERATOR

may have collected debris. To clean, remove AERATOR and rinse with water and
remove any debris. Turn on faucet to wash any debris out of the faucet. Thread
AERATOR back into spout. Operate faucet.

A E R AT O R

3

1

2

7

11

13

12

4

5

6

8

10

9

SPOUT
HUB

CHECK CONNECTIONS

FOR LEAKS

6

PRY RED RING FORWARD

AND ROTATE COUNTER-

CLOCKWISE ONE CLICK

PRY RED RING FORWARD

AND ROTATE CLOCKWISE 

"A"

ADJUSTMENT WHEN

WATER IS TOO HOT

"A"

"A"

"B"

ADJUSTMENT WHEN

WATER IS TOO COLD

"B"

"RED RING"- HOT

LIMIT SAFETY STOP

TEMPERATURE

SETTING NUMBERS

   0

     1

     2

    3

    4

    

 5

    

 6

    

5

By restricting handle rotation and limiting the amount of hot water allowed
to mix with the cold, the HOT LIMIT SAFETY STOP reduces risk of accidental
scalding. To set the maximum hot water temperature of your faucets, all you
need to do is adjust the setting on the HOT LIMIT SAFETY STOP. 

Remove HANDLE BUTTON 

(1)

 and loosen SET SCREW 

(2)

. Pull

HANDLE 

(3)

 off valve stem. Pull off CAP 

(4)

. Use a flat blade

screwdriver or your fingers to pull up and rotate red 
HOT LIMIT SAFETY STOP 

(5)

. Follow Step "A" or "B" to adjust 

min./max.discharge temperature. "0" being the hottest to 
"7" the coldest temperature setting.  Factory set at "0".

Replace ESCUTCHEON CAP 

(4)

, HANDLE 

(3)

, tighten

HANDLE SCREW 

(1)

 and install INDEX BUTTON 

(2)

.

HOT LIMIT SAFETY STOP ADJUSTMENT

"B"

Reviews: