background image

M 9 6 8 9 8 6   Rev.  1. 3

CHECK CONNECTIONS FOR LEAKS.

Move HANDLE down into "off" position.
Turn on water supplies and check connections for leaks

.

Operate HANDLE 

(2)

 up and down, left and right to flush

water lines thoroughly.
Operate HAND SPRAY and check connections for leaks.

CHECK CONNECTIONS

FOR LEAKS

5

SERVICE

6

Clogged CARTRIDGE outlets or inlets may cause reduced flow.

To clean, first turn off water supply then:

1

2

3

4

5

6

8

7

7

If faucet drips, operate HANDLE several times from "off" to "on." Do not

apply excessive force.

FLOW CONTROL DEVICE may accumulate dirt. To remove the FLOW CONTROL DEVICE,

unthread SPRAY AND HOSE ASSEMBLY and rinse clean FLOW CONTROL DEVICE.

Remove INDEX BUTTON 

(1)

, loosen HANDLE SCREW 

(2)

 and remove HANDLE 

(3)

.

Unthread the ESCUTCHEON CAP 

(4)

. Unthread three MOUNTING SCREWS 

(5)

.

Lift CARTRIDGE 

(6)

 off MANIFOLD 

(7)

 and remove CARTRIDGE SEALS 

(8)

.

Place SEALS 

(8)

 into CARTRIDGE PORTS 

(6A)

.

Replace ESCUTCHEON CAP 

(4)

, HANDLE 

(3)

, tighten HANDLE

SCREW 

(1)

 and install INDEX BUTTON 

(2)

.

Clean MANIFOLD 

(7)

, CARTRIDGE 

(6)

 ports and SEALS 

(8)

.

Place CARTRIDGE 

(6)

 onto MANIFOLD 

(7)

 and tighten MOUNTING

SCREWS 

(5)

 alternately.

 

By restricting handle rotation and limiting the amount of hot water allowed

to mix with the cold, the HOT LIMIT SAFETY STOP reduces risk of accidental

scalding. To set the maximum hot water temperature of your faucets, all you

need to do is adjust the setting on the HOT LIMIT SAFETY STOP. 
Remove HANDLE BUTTON 

(1)

 and loosen SET SCREW 

(2)

. Pull

HANDLE 

(3)

 off valve stem. Pull off CAP 

(4)

. Use a flat blade

screwdriver or your fingers to pull up and rotate red HOT LIMIT

SAFETY STOP 

(5)

. Follow 

Step "A" or "B"

 to adjust min./max.

discharge temperature. "0" being the hottest to "7" the coldest

temperature setting. Factory set at "0".

Replace ESCUTCHEON CAP 

(4)

, HANDLE 

(3)

, tighten

HANDLE SCREW 

(1)

 and install INDEX BUTTON 

(2)

.

HOT LIMIT SAFETY STOP ADJUSTMENT

6

PRY RED RING FORWARD

AND ROTATE COUNTER-

CLOCKWISE ONE CLICK

PRY RED RING FORWARD

AND ROTATE CLOCKWISE 

"A"

ADJUSTMENT WHEN

WATER IS TOO HOT

"A"

"A"

"B"

"B"

ADJUSTMENT WHEN

WATER IS TOO COLD

"B"

"RED RING"- HOT
LIMIT SAFETY STOP

TEMPERATURE

SETTING NUMBERS

   0

     

1    

 2  

  3

    

4  

   5

    

 6

    

5

6A

CARE:

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH  CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A

CLOTH WITH A COARSE SURFACE.

FLOW CONTROL

DEVISE

SPRAY AND HOSE

ASSEMBLY

Reviews: