CHECK DRAIN CONNECTIONS
10
11
12
TEST INSTALLED FITTING
With HANDLES
(1)
in OFF position, turn on WATER
SUPPLIES
(2)
and check all connections for leaks.
Remove AERATOR
(3)
.
Operate both HANDLES
(1)
to flush water
lines thoroughly.
Replace AERATOR
(3)
.
1
HOT
COLD
2
4
2
1
5
“P” TRAP
WASTE
OUTLET
3
Operate POP-UP KNOB
(5)
and fill Sink with water. Check
that DRAIN STOPPER
(4)
makes a good seal and retains
water in Sink. If STOPPER
(4)
does not seal properly, please
refer to “Troubleshooting Guide” in these instructions.
Release POP-UP KNOB
(5)
down and check all drain
connections and "P" trap for leaks. Tighten
if necessary.
4
2
1
1
3
5
4
9
INSTALL HANDLE TRIM
LEVER HANDLE
ACRYLIC HANDLE
Turn HANDLE STEM
(1)
to "OFF" position.
Place the HANDLE ADAPTER
(2)
on the HANDLE STEM
(1)
. Install the
ADAPTER SCREW
(3)
and tighten securely.
Position LEVER HANDLE
(4)
and place on ADAPTER
(2)
. Install the
HANDLE SCREW
(5)
and tighten securely.
M 9 6 8 8 8 6
CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT CLEAN
WITH CLEAR WATER. DRY WITH A SOFT
COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT
WITH SOAPS, ACID, POLISH, ABRASIVES,
HARSH CLEANERS, OR A CLOTH WITH A
COARSE SURFACE.
SERVICE
If spout drips, operate handles several
times from OFF to ON position. Do not
force - handles turn only 90˚.
1
4
3
5
2
To change direction of handle
rotation, proceed as follows:
Loosen HANDLE SCREW
(1)
.
Turn VALVE to OFF position.
Pull HANDLE
(2)
off ADAPTER
(3)
. Loosen ADAPTER
SCREW
(4)
and pull off ADAPTER
(3)
.
Turn ADAPTER
(3)
90˚ in a way that flat in ADAPTER
(3)
catches on the other FLAT on VALVE STEM
(5)
.
Tighten HANDLE SCREW
(1)
.
Reinstall ADAPTER SCREW
(4)
and LEVER HANDLE
(2)
.
13
Turn HANDLE STEM
(1)
to "OFF" position.
Place the HANDLE ADAPTER
(2)
on the HANDLE STEM
(1)
.
Position ACRYLIC HANDLE
(3)
and install on ADAPTER
(2)
. Install the
HANDLE SCREW
(4)
and tighten securely.
Push in INDEX BUTTON
(5)
. (Hot-left side, Cold-Right side)
2
4
3
5
H