background image

M 9 6 8 7 9 6   R e v. 1 . 1

CHECK DRAIN CONNECTIONS

12

13

TEST INSTALLED FITTING

With HANDLES 

(1)

 in OFF position, turn on WATER

SUPPLIES

(2)

 and check all connections for leaks.

Operate both HANDLES 

(1)

 to flush water

lines thoroughly.

Rotate TRANSFER VALVE 

(5)

 from rim wash to 

spray several times to check operation.

Pull up POP-UP KNOB 

(3)

 and fill Bidet with water. Check

that DRAIN STOPPER 

(4)

 makes a good seal and retains

water in Bidet. If STOPPER 

(4)

  does not seal properly,

please refer to “Troubleshooting Guide” in these instructions.

Push POP-UP KNOB 

(3)

 down and check all drain

connections and "P" trap for leaks.     Tighten
if necessary.

2

2

1

1

5

3

4

SPRAY

4

14

American Standard’s EverClean
finish will wipe clean with a soft,
dry cloth.
A soft cloth with clean water
may also be used, if desired.
No additional cleaning products
are required.

DO NOT USE: Soaps, acid,
polish, abrasives, harsh
cleaners, or a cloth with a
coarse surface.

EverClean™ Finish
Care Instructions

INSTALL HANDLES (Lever)

INSTALL HANDLES (Acrylic)

11

5

3

2

1

1

2

Turn HANDLE STEM (1) to "OFF"

position.

Place the ACRYLIC HANDLE (2)

on the HANDLE STEM (1).

Install the HANDLE SCREW (3)

and tighten securely.

Push in INDEX BUTTON (4).

Turn HANDLE STEM 

(1)

 to "OFF"

position.

Place the HANDLE ADAPTER 

(2)

on the HANDLE STEM 

(1).

Install the ADAPTER SCREW 

(3)

and tighten securely. Position

LEVER HANDLE 

(4)

 and place

on ADAPTER 

(2)

.

Install the HANDLE SCREW 

(5)

and tighten securely with hex

wrench supplied.

4

3

4

H

SERVICE

If spout drips, operate handles several

times from OFF to ON position. Do not

force - handles turn only 90˚.

1

4

3

5

2

To change direction of handle
rotation, proceed as follows:

Loosen  HANDLE SCREW (1) .

Turn VALVE to OFF position.

Pull HANDLE (2) off ADAPTER (3). Loosen  ADAPTER

SCREW (4) and pull off ADAPTER (3).

Turn ADAPTER (3) 90˚ in a way that flat in ADAPTER (3)

catches on the other FLAT on VALVE STEM (5).

Tighten HANDLE SCREW (1).

Reinstall ADAPTER SCREW (4) and LEVER HANDLE (2).

15

Summary of Contents for Colony/Colony Soft 3475.301

Page 1: ...Tighten LOCKNUTS 1 with WRENCH 5 supplied to secure VALVE BODIES 3 3a Install LOCKNUT 1 and RUBBER WASHER 2 onto VALVE BODIES 3 3a From under side of mounting surface install VALVE BODY 3 3a through valve mounting holes Threads of VALVE BODY 3 3a should extent at least 5 16 of a inch above mounting surface top Fig A Thread ADAPTER 4 onto VALVE BODIES 3 3a until snug against internal stop If necess...

Page 2: ...ASKET NOT VISIBLE Insert LIFT ROD GUIDE 1 and CABLE CONNECTOR 2 through rear hole making sure SEAL WASHER 3 is properly seated Fig B From below slip slot in MOUNTING NUT 4 over CABLE 5 Thread NUT 4 onto lift rod guide shank to secure ROD GUIDE 1 to bidet Hand tighten only Fig B 1 2 4 5 3 ILLUSTRATION SHOWN LESS VALVES SLOTTED MOUNTING NUT POP UP ROD ASSEMBLY TIGHTEN LOCKNUT 1 Fig A Fig B Tighten L...

Page 3: ...P KNOB 1 must be fully down Fig A Thread CABLE CONNECTOR 1 clockwise onto DRAIN BODY CONNECTION 2 and hand tighten Fig B Your new POP UP DRAIN installation is now complete Fig C Note Tailpeice on pop up drain is 1 1 4 O D Fig C Fig B ATTACH CABLE CONNECTOR 8 Operate LIFT KNOB 1 to verify that STOPPER 2 opens and closes Note If STOPPER 2 does not open and close properly then refer to the troublesho...

Page 4: ...olish abrasives harsh cleaners or a cloth with a coarse surface EverClean Finish Care Instructions INSTALL HANDLES Lever INSTALL HANDLES Acrylic 11 5 3 2 1 1 2 Turn HANDLE STEM 1 to OFF position Place the ACRYLIC HANDLE 2 on the HANDLE STEM 1 Install the HANDLE SCREW 3 and tighten securely Push in INDEX BUTTON 4 Turn HANDLE STEM 1 to OFF position Place the HANDLE ADAPTER 2 on the HANDLE STEM 1 Ins...

Page 5: ...llow CABLE ADJUSTMENT PROCEDURE If you need to remove the Stopper Follow STOPPER REMOVAL PROCEDURE If you would like the ability to remove your Stopper simply by lifting it out of the drain Follow STOPPER INSTALLATION PROCEDURE for Unlocked mode Fig B Fig A REMOVE CAM Fig E Disconnect the Cable from the Drain by threading the Cable Connector 1 counter clockwise Fig A Look at the area on the Drain ...

Page 6: ...ok at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig H To install the stopper in Unlocked mode insert the Stopper into the Drain so that the Plastic Loop is facing toward the front of the Sink and the American Standard logo is facing rear Rotate Stopper slightly if necessary so that the Stopper slides all the way down Fig H Re install the C...

Reviews: