M 9 6 8 7 9 6 R e v. 1 . 1
CHECK DRAIN CONNECTIONS
12
13
TEST INSTALLED FITTING
With HANDLES
(1)
in OFF position, turn on WATER
SUPPLIES
(2)
and check all connections for leaks.
Operate both HANDLES
(1)
to flush water
lines thoroughly.
Rotate TRANSFER VALVE
(5)
from rim wash to
spray several times to check operation.
Pull up POP-UP KNOB
(3)
and fill Bidet with water. Check
that DRAIN STOPPER
(4)
makes a good seal and retains
water in Bidet. If STOPPER
(4)
does not seal properly,
please refer to “Troubleshooting Guide” in these instructions.
Push POP-UP KNOB
(3)
down and check all drain
connections and "P" trap for leaks. Tighten
if necessary.
2
2
1
1
5
3
4
SPRAY
4
14
American Standard’s EverClean
finish will wipe clean with a soft,
dry cloth.
A soft cloth with clean water
may also be used, if desired.
No additional cleaning products
are required.
DO NOT USE: Soaps, acid,
polish, abrasives, harsh
cleaners, or a cloth with a
coarse surface.
EverClean™ Finish
Care Instructions
INSTALL HANDLES (Lever)
INSTALL HANDLES (Acrylic)
11
5
3
2
1
1
2
Turn HANDLE STEM (1) to "OFF"
position.
Place the ACRYLIC HANDLE (2)
on the HANDLE STEM (1).
Install the HANDLE SCREW (3)
and tighten securely.
Push in INDEX BUTTON (4).
Turn HANDLE STEM
(1)
to "OFF"
position.
Place the HANDLE ADAPTER
(2)
on the HANDLE STEM
(1).
Install the ADAPTER SCREW
(3)
and tighten securely. Position
LEVER HANDLE
(4)
and place
on ADAPTER
(2)
.
Install the HANDLE SCREW
(5)
and tighten securely with hex
wrench supplied.
4
3
4
H
SERVICE
If spout drips, operate handles several
times from OFF to ON position. Do not
force - handles turn only 90˚.
1
4
3
5
2
To change direction of handle
rotation, proceed as follows:
Loosen HANDLE SCREW (1) .
Turn VALVE to OFF position.
Pull HANDLE (2) off ADAPTER (3). Loosen ADAPTER
SCREW (4) and pull off ADAPTER (3).
Turn ADAPTER (3) 90˚ in a way that flat in ADAPTER (3)
catches on the other FLAT on VALVE STEM (5).
Tighten HANDLE SCREW (1).
Reinstall ADAPTER SCREW (4) and LEVER HANDLE (2).
15