background image

M 9 6 8 7 9 6   R e v. 1 . 1

3475.301
3475.501

COLONY/COLONY SOFT

3

5

4

4

Certified to comply with ANSI A112.18.1

Installation

Instructions

Turn off hot and cold water
supplies before beginning.

CAUTION

1

BIDET FAUCET INSTALLATION

Replace UPPER GASKET 

(8) 

and WASHER 

(7)

 . Position

the side threaded outlet rearward and secure MOUNTING
NUT

(6)

. Thread ESCUTCHEON 

(11)

 onto TRANSFER

VALVE 

(9)

until it seats against the BIDET LEDGE. 

Remove MOUNTING NUT 

(6)

, WASHER

 (7)

 and

UPPER GASKET 

(8)

from TRANSFER VALVE 

(9).

Insert TRANSFER VALVE 

(9)

 into the center forward

hole of BIDET.

COLD

HOT

BIDET

LEDGE

10

4

3a

3

8

9

1

5

2

6

11

Roughing-in Dimensions

FINISHED
FLOOR

DIVERTER AND
VACUUM BREAKER
ASSEMBLY

1-1/4 MAX.

1-3/16 DIA.

(C)

(H)

4-1/4

FOR GROUND JOINT
CONNECTION OR 1/2 "
O.D. SLIP (INLETS) 

REAR VIEW WITH

WALL REMOVED

8 TO 12

2-1/4
DIA.

SPRAY INSTALLATION

2

Assemble SPRAY BODY 

(1)

 to BIDET. Using putty, seal underside

of SPRAY BODY FLANGE 

(2)

 and secure with NUT 

(3)

.

Thread SPRAY CAP 

(9)

 onto SPRAY BODY 

(1)

.

Thread SPRAY HOSE 

(4)

 with SEAL WASHER 

(5)

 to SPRAY BODY 

(1)

.

Connect other end of HOSE 

(4)

 with SEAL WASHER 

(6)

 to side outlet

NIPPLE

(7)

 of the TRANSFER VALVE 

(8)

.

PUTTY

6

2

7

8

1

9

Tighten LOCKNUTS 

(1)

 with WRENCH 

(5)

 (supplied)

to secure VALVE BODIES 

(3, 3a)

.

Install LOCKNUT 

(1)

 and RUBBER WASHER 

(2)

 onto VALVE BODIES 

(3, 3a)

. From

under side of mounting surface, install VALVE BODY 

(3, 3a)

 through valve mounting

holes. Threads of VALVE BODY 

(3, 3a)

 should extent at least 5/16 of a inch above

mounting surface top. 

Fig. A.

Thread ADAPTER 

(4)

onto VALVE BODIES 

(3, 3a)

until snug against internal stop. If necessary, adjust LOCKNUT 

(1)

.

Place RUBBER RING 

(10)

 into ADAPTER 

(4)

.

MOUNTING

SURFACE

10

2
1

3, 3a

5/16''

MIN.

Fig. A.

7

Adjustable Wrench

 Screwdriver

Channel Locks

Required tools

Tubing Cutter

Phillips Screwdriver

Plumbers' Putty or

Caulking

1

BIDET OUTLINE
IS SYMBOLIC

FINISHED
WALL

1-1/4 O.D. TAILPIECE

DOUCHE
SPRAY

2-1/8

DIA.

ADJ. 1-1/4

TO 2-1/4

3-7/8

5-1/2

1-3/8

DIA.

7/8 DIA.

TRANSFER VALVE

(FOR FLUSHING
RIM OR SPRAY)

4

Bidet Faucet and Transfer Valve

with SpeedConnect™ Drain

Congratulations on purchasing your American
Standard faucet with Speed Connect drain,  a
feature found only on American Standard faucets.

*Your new American Standard faucet is designed to work only with the SpeedConnect drain. 

To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.

SpeedConnect Drain*

•  Fewer parts, installs in less time
•  Never needs adjustment
•  Guaranteed to seal properly the first time, every time.

Summary of Contents for Colony/Colony Soft 3475.301

Page 1: ...Tighten LOCKNUTS 1 with WRENCH 5 supplied to secure VALVE BODIES 3 3a Install LOCKNUT 1 and RUBBER WASHER 2 onto VALVE BODIES 3 3a From under side of mounting surface install VALVE BODY 3 3a through valve mounting holes Threads of VALVE BODY 3 3a should extent at least 5 16 of a inch above mounting surface top Fig A Thread ADAPTER 4 onto VALVE BODIES 3 3a until snug against internal stop If necess...

Page 2: ...ASKET NOT VISIBLE Insert LIFT ROD GUIDE 1 and CABLE CONNECTOR 2 through rear hole making sure SEAL WASHER 3 is properly seated Fig B From below slip slot in MOUNTING NUT 4 over CABLE 5 Thread NUT 4 onto lift rod guide shank to secure ROD GUIDE 1 to bidet Hand tighten only Fig B 1 2 4 5 3 ILLUSTRATION SHOWN LESS VALVES SLOTTED MOUNTING NUT POP UP ROD ASSEMBLY TIGHTEN LOCKNUT 1 Fig A Fig B Tighten L...

Page 3: ...P KNOB 1 must be fully down Fig A Thread CABLE CONNECTOR 1 clockwise onto DRAIN BODY CONNECTION 2 and hand tighten Fig B Your new POP UP DRAIN installation is now complete Fig C Note Tailpeice on pop up drain is 1 1 4 O D Fig C Fig B ATTACH CABLE CONNECTOR 8 Operate LIFT KNOB 1 to verify that STOPPER 2 opens and closes Note If STOPPER 2 does not open and close properly then refer to the troublesho...

Page 4: ...olish abrasives harsh cleaners or a cloth with a coarse surface EverClean Finish Care Instructions INSTALL HANDLES Lever INSTALL HANDLES Acrylic 11 5 3 2 1 1 2 Turn HANDLE STEM 1 to OFF position Place the ACRYLIC HANDLE 2 on the HANDLE STEM 1 Install the HANDLE SCREW 3 and tighten securely Push in INDEX BUTTON 4 Turn HANDLE STEM 1 to OFF position Place the HANDLE ADAPTER 2 on the HANDLE STEM 1 Ins...

Page 5: ...llow CABLE ADJUSTMENT PROCEDURE If you need to remove the Stopper Follow STOPPER REMOVAL PROCEDURE If you would like the ability to remove your Stopper simply by lifting it out of the drain Follow STOPPER INSTALLATION PROCEDURE for Unlocked mode Fig B Fig A REMOVE CAM Fig E Disconnect the Cable from the Drain by threading the Cable Connector 1 counter clockwise Fig A Look at the area on the Drain ...

Page 6: ...ok at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig H To install the stopper in Unlocked mode insert the Stopper into the Drain so that the Plastic Loop is facing toward the front of the Sink and the American Standard logo is facing rear Rotate Stopper slightly if necessary so that the Stopper slides all the way down Fig H Re install the C...

Reviews: