American Standard Colony 1.6 G.P.F. Toilet 2359 Installation Instructions Download Page 4

7 3 0 1 1 8 6 - 1 0 0   R e v .   B

-   4   -

12a

12d

12f

12e

12c

 INSTRUCTIONS TO INSTALL TOILET SEAT

Place seat on bowl. Be careful to 
center hinge over holes in bowl.

Insert bolts in hinges.

Attach the nut from below.

Use a screwdriver to tighten bolt.

Close the hinge covers.

12b

13

 

• Make sure water supply
  is off. Remove valve TOP
  by lifting arm and rotating
  top and arm 1/8 turn
  counterclockwise, pressing  
  down slightly on cap.

IMPORTANT: Always 
clear sand and rust 
from system.

• While holding a
  container over the
  uncapped VALVE to
  prevent splashing, turn
  water supply on and off
  a few times. Leave
  water supply off.

• 

Replace TOP by engaging

  lugs and rotating 1/8 turn
  clockwise. MAKE
  CERTAIN TIP IS TURNED
  TO THE LOCKED
  POSITION. VALVE MAY
  NOT TURN ON IF TOP IS
  NOT FULLY TURNED TO
  THE LOCKED POSITION.

For troubleshooting information please contact:

TROUBLESHOOTING

IF FILL VALVE SHUTS OFF BUT CONTINUES TO LEAK 
SLOWLY, 

repeat Step 13.

IF FILL VALVE TURNS OFF AND ON DURING PERIODS OF 
NON-USE, 

it is a signal you are wasting water because:

• The end of the refill tube is inserted into overflow pipe, below
   water level in tank. Attach refill tube to overflow pipe using "S"
   clip provided.

• The flush valve is leaking because it's worn, dirty or misaligned
   with tank ball or flapper (replace with a new flapper).

IF FILL VALVE WON'T TURN ON OR SHUT OFF or REFILL 
OF TANK WATER IS SLOW after valve has been in use for 
some time, 

Fluidmaster Model 242 Replacement Seal may be 

needed.

Go to our website at www.fluidmaster.com for more 
solutions to toilet problems.

©  2001 Fluidmaster, Inc.
®  Registered trademark of Fluidmaster, Inc.

GUARANTEE: 

This Fluidmaster product is guaranteed to be free from defective materials and 

workmanship for a period of one year. Units returned to Fluidmaster will be replaced without charge.

Always use quality Fluidmaster repair parts when maintaining your Fluidmaster products. Fluidmaster 
shall not be responsible or liable for any damages caused by products used with Fluidmaster valves 
that were not manufactured by Fluidmaster, Inc.

30800 Rancho Viejo Road

San Juan Capistrano, CA 92675

(949) 728-2000  (800) 631-2011

www.fluidmaster.com

LIFT ARM

FIRST

NOTE

Pictures are representative and may not 

            exactly depict the flush valve.

TOILET SEAT CARE AND CLEANING

When cleaning your toilet seat wash it 
with mild, soapy water: rinse the seat 
thoroughly with clear water: and dry 
with a soft cloth.

Avoid detergents, disinfectants, or 
cleaning products in aerosol cans. 
NEVER use abrasive scouring powders 
on your seat. Some bathroom 
chemicals and cosmetics may damage 
the seat's finish. After installation, check 
the tightness of the bolts from time to 
time to ensure a tight fit.

Summary of Contents for Colony 1.6 G.P.F. Toilet 2359

Page 1: ... u c t n a m e s l i s t e d h e r e i n a r e t r a d e m a r k s o f A S A m e r i c a I n c A S A m e r i c a I n c 2 0 0 8 NOTE Pictures may not exactly define contour of china and components ROUGHING IN DIMENSIONS NOTE Distance from wall to closet flange centerline must be as listed below A 12 305mm A WAX RING SEALANT 5 4 INSTALL WAX SEAL Invert toilet on floor cushion to prevent damage and i...

Page 2: ...T RUBBER WASHER 9a 9b Before continuing determine the type of water supply connecation you have from the chart below and use the appropriate assembly parts required to properly reconnect the water supply DO NOT use plumber s putty to seal these fittings CAUTION DO NOT USE CONE WASHER WITH PLASTIC SUPPLY LINE These parts must be used as illustrated to insure water tight connection Use of existing c...

Page 3: ...IDMASTER FLUSHVALVE TANK COUPLING KIT 232 FLUIDMASTER FLAPPER ASSEMBLY FLUIDMASTER FLAPPER ASSEMBLY TRIP LEVER ASSEMBLY LH BOLT CAP KIT 128 SEAT CARE AND CLEANING When cleaning your toilet wash it with mild soapy water rinse thoroughly with clear water and dry with a soft cloth Avoid detergents disinfectants or cleaning products in aerosol cans NEVER use abrasive scouring powders or abrasive pads ...

Page 4: ...ank ball or flapper replace with a new flapper IF FILL VALVE WON T TURN ON OR SHUT OFF or REFILL OF TANK WATER IS SLOW after valve has been in use for some time Fluidmaster Model 242 Replacement Seal may be needed Go to our website at www fluidmaster com for more solutions to toilet problems 2001 Fluidmaster Inc Registered trademark of Fluidmaster Inc GUARANTEE This Fluidmaster product is guarante...

Page 5: ...product model and of the defect be sent to the following address TROUBLESHOOTING GUIDE PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION Does not flush a Water supply valve closed a Open valve and allow water to fill tank b Supply line blocked b Shut off water supply disconnect supply line and inspect all gaskets and washers Reassemble Also see Fluidmaster maintenance see step 13 c Flush valve chain too lo...