SERVICE
10
TEST INSTALLED FITTING
With HANDLES
(1)
in OFF position, turn on WATER
SUPPLIES
(2)
and check all connections for leaks.
Remove AERATOR
(3)
.
Operate both HANDLES
(1)
to flush water lines thoroughly.
Replace AERATOR
(3)
.
1
5
2
CHECK DRAIN CONNECTIONS
Operate POP-UP KNOB
(4)
and fill lavatory with water.
Check that DRAIN STOPPER
(5)
makes a good seal
and retains water in SINK. If DRAIN STOPPER
(5)
does not seal properly, please refer to Troubleshooting
section in these instructions.
Release POP-UP KNOB
(4)
down and check all drain
connections and
"P"
trap for leaks. Tighten
if necessary.
90˚
12
11
“P” TRAP
FLAT
WASTE
OUTLET
If spout drips, operate handles several times
from OFF to ON position. Do not force - handles
turn only 90˚.
To change direction of handle rotation, proceed as follows:
1
2
3
5
4
4
3
Turn VALVE in OFF position.
Loosen HANDLE SCREW
(1)
.
Pull HANDLE
(2)
off ADAPTER
(3)
. Loosen ADAPTER
SCREW
(4)
and pull off ADAPTER
(3)
.
Turn ADAPTER
(3)
90˚ in a way that
flat
in ADAPTER
(3)
catches the other
flat
on VALVE STEM
(5)
.
Reinstall ADAPTER SCREW (
4)
and LEVER HANDLE
(2)
.
Tighten HANDLE SCREW
(1)
.
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER.DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
CARE INSTRUCTIONS: