CADET™ CORNER
WHIRLPOOL & BATHING POOL
HIGH GLOSS ACRYLIC
© 2003 American Standard Inc.
1524mm
(60)
70mm REF.
(2-3/4)
165mm
(6-1/2)
279mm
(11)
RECOMMENDED
FITTING LOCATION
64 X 330mm (2-1/2 X 13)
229 X 305mm
(9 X 12)
CUTOUT IN
FLOOR FOR
DRAIN
ON/OFF
SWITCH
PROVIDE ACCESS
TO PUMP FOR
SERVICING ON ALL
INSTALLATIONS
OUTLINE OF
CUTOUT
2159mm
(85)
1080 mm
(42-1/2)
C/L
1524mm
(60)
1076mm
(42-3/8)
1080mm
(42-1/2)
PUMP
C/L OF
DRAIN OUTLET
1-1/2 O.D. TAILPIECE
LEVELING STRINGER
NOT FOR SUPPORT
70mm
(2-3/4)
117mm
(4-5/8)
1-1/2 N.P.T.M.
THREADS
38 mm REF.
(1-1/2)
C/L OF
OVERFLOW
76mm
(3)
464mm
(18-1/4)
502mm
(19-3/4)
ROUGH
FLOOR
INTEGRAL
SUPPORT
FEET
SAFE-T-
HEATER
REMOVABLE
BLANK
INTEGRAL
FEET
1524mm
(60)
70mm REF.
(2-3/4)
165mm
(6-1/2)
279mm
(11)
RECOMMENDED
FITTING LOCATION
64 X 330mm (2-1/2 X 13)
229 X 305mm
(9 X 12)
CUTOUT IN
FLOOR
FOR
DRAIN
OUTLINE OF
CUTOUT
2159mm
(85)
1080 mm
(42-1/2)
C/L
1524mm
(60)
1076mm
(42-3/8)
C/L OF
DRAIN OUTLET
1-1/2 O.D. TAILPIECE
LEVELING STRINGER
NOT FOR SUPPORT
70mm
(2-3/4)
117mm
(4-5/8)
1-1/2 N.P.T.M.
THREADS
38 mm REF.
(1-1/2)
C/L OF
OVERFLOW
76mm
(3)
464mm
(18-1/4)
502mm
(19-3/4)
ROUGH
FLOOR
85 X 60 X 19-3/4In.(2159 X 1524 X 502mm)
130 Lbs. (59 Kg.)
756 Lbs. (343 Kg.)
75 Gal. (284 L.)
60 Gal. (227 L.)
32 X 32 In. (813 mm X 813 mm)
46 X 46 In. (1168 X 1168mm)
14 In. (356 mm)
34 Lbs./Sq. Ft. (115 Kgs/Sq. m.)
41.7
70.4
GENERAL SPECIFICATIONS FOR 2775 WHIRLPOOL
INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
MIN. OPERATING GAL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT3)
WHIRLPOOL ELECTRICAL SPECIFICATIONS
2.1 HP, 14.4 AMPS, 120V.
SYSTEM I PUMP
85 X 60 X 19-3/4In.
(2159mm X 1524 mm X 502mm)
105 Lbs. (48 Kg.)
730 Lbs. (328 Kg.)
75 Gal. (284 L.)
32 X 32 In. (813 mm X 813 mm)
46 X 46 In. (1168 X 1168mm)
14 In. (356 mm)
33 Lbs./Sq. Ft. (111 Kgs/Sq. m.)
41.7
70.4
GENERAL SPECIFICATIONS FOR 2775 BATHING POOL
INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT3)
NOTES:
BATH CAN BE INSTALLED EITHER ABOVE OR BELOW FLOOR LINE AS PIER, ISLAND, OR PENINSULA
TYPE INSTALLATION. SUMP OF BATH IS SUPPORTED BY INTEGRAL FEET. NO ADDITIONAL SUPPORT
REQUIRED. ENCLOSING MATERIAL BY OTHERS.
REFER TO INSTALLATION INSTRUCTIONS SUPPLIED WITH WHIRLPOOL FOR ADDITIONAL
INFORMATION.
OPTIONAL 2 WALL TILING BEAD KIT AVAILABLE AND MUST BE ORDERED SEPARATELY.
FITTINGS NOT INCLUDED AND MUST BE ORDERED SEPARATELY.
PROVIDE SUITABLE REINFORCEMENT FOR ALL SUPPORTS.
IMPORTANT:
Dimensions of fixtures are nominal and may vary within the range of tolerances established by ANSI
Standard Z124.1/A112.19.7M.
These measurements are subject to change or cancellation. No responsibility is assumed for use of
superseded or voided leaflet.
■