background image

H64

© 2008 AS America Inc.

CADET™ 5' x 32"

WHIRLPOOL AND BATHING POOL

HIGH GLOSS

Revised 2/08

464 mm
(18-1/4)

38 mm

(1-1/2)

502 mm
(19-3/4)

1-1/2 O.D.TAILPIECE

INTEGRAL

SUPPORT

FEET

   LEVELING 
   STRINGER 
   NOT FOR 
   SUPPORT 

ROUGH

FLOOR

70mm

(2-3/4)

305 mm

(12)

OPTIONAL TO 

FINISHED FLOOR 

USUALLY BETWEEN

1651 & 1981mm 

(65 & 78)

C/L OF
OVERFLOW

102 mm

(4)

C/L OF
SPOUT

C/L OF
VALVES

C/L OF
SHOWER ARM

70 mm

(2-3/4)

 117 mm

(4-5/8)

1-1/2 N.P.T.M.

THREADS

1521 mm

(59-7/8)

806 mm
(31-3/4)

OUTLINE OF CUTOUT 
1483 mm x 768 mm
(58-3/8 X 30-1/4 )

403 mm
(15-7/8)

222 mm

(8-3/4)

305 mm

(12)

60mm

(2-3/8)

(8) JETS

CUTOUT IN FLOOR
FOR DRAIN

PUMP

FINISHED

WALL

19 mm

(3/4)

229 mm

(9)

C/L OF

SUPPLIES

C/L OF DRAIN

SEE FITTING

SPECS FOR

DIMENSIONS

(2) AIR VALVES

ON/OFF
SWITCH

PROVIDE ACCESS TO PUMP FOR

SERVICING ON ALL INSTALLATIONS

INTEGRAL

SUPPORT

FEET

464 mm
(18-1/4)

38 mm

(1-1/2)

502 mm
(19-3/4)

1-1/2 O.D.TAILPIECE

LEVELING STRINGER

NOT FOR SUPPORT 

ROUGH

FLOOR

1521 mm

(59-7/8)

806 mm
(31-3/4)

OUTLINE OF CUTOUT 
1473 mm x 768 mm
(58 X 30-1/4 )

403 mm
(15-7/8)

222 mm

(8-3/4)

305 mm

(12)

60mm

(2-3/8)

70mm

(2-3/4)

CUTOUT IN FLOOR
FOR DRAIN

FINISHED

WALL

305 mm

(12)

OPTIONAL TO 

FINISHED FLOOR 

USUALLY BETWEEN

1651 & 1981mm 

(65 & 78)

C/L OF
OVERFLOW

102 mm

(4)

C/L OF
SPOUT

C/L OF
VALVES

C/L OF
SHOWER ARM

70 mm

(2-3/4)

 117 mm

(4-5/8)

1-1/2 N.P.T.M.

THREADS

19 mm

(3/4)

229 mm

(9)

C/L OF

SUPPLIES

C/L OF DRAIN

SEE FITTING

SPECS FOR

DIMENSIONS

  59-7/8 x 31-3/4 x 19-3/4 In. (1521 x 806 x 502mm)

85 Lbs. (39 Kg.)

535 Lbs. (243 Kg.)

54 Gal. (204 L.)
49 Gal. (186 L.)

20 x 40 In. (508mm x 1016mm)

53-1/2 x 26 In. (1359mm x 699mm)

14 In. (356mm)

41 Lbs./Sq. Ft. (197 Kgs/Sq. m.)

15.6
29.6

GENERAL SPECIFICATIONS FOR 2770 WHIRLPOOL

INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
MIN. OPERATING GAL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT3)

WHIRLPOOL ELECTRICAL SPECIFICATIONS

1.25 HP, 9.9 AMPS, 120V.

SYSTEM I PUMP

  59-7/8 x 31-3/4 x 19-3/4 In.

(1521mm x 806 mm x 502mm)

62 Lbs. (28 Kg.)

512 Lbs. (233 Kg.)

54 Gal. (204 L.)

20 x 40 In. (508mm x 1016mm)

53-1/2 x 26 In. (1359mm x 699mm)

14 In. (356mm)

39 Lbs./Sq. Ft. (189 Kgs/Sq. m.)

15.6
29.6

GENERAL SPECIFICATIONS FOR 2770 BATHING POOL

INSTALLED SIZE

WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT3)

NOTES:

BATH CAN BE INSTALLED EITHER ABOVE OR BELOW FLOOR LINE AS PIER, ISLAND, OR PENINSULA TYPE INSTALLATION. SUMP OF 

BATH IS SUPPORTED BY INTEGRAL FEET. NO ADDITIONAL SUPPORT REQUIRED. ENCLOSING MATERIAL BY OTHERS.

■ 

REFER TO INSTALLATION INSTRUCTIONS SUPPLIED WITH WHIRLPOOL FOR ADDITIONAL INFORMATION.

OPTIONAL 3 WALL TILING BEAD. KIT AND APRON NO. 9260.018 OR 9360.018 AVAILABLE AND MUST BE ORDERED SEPARATELY.

FITTINGS NOT INCLUDED AND MUST BE ORDERED SEPARATELY.

PROVIDE SUITABLE REINFORCEMENT FOR ALL SUPPORTS.

IMPORTANT: Dimensions of fixtures are nominal and may vary within the range of tolerances established by ANSI Standard Z124.1

These measurements are subject to change or cancellation. No responsibility is assumed for use of superseded or voided leaflet.

Reviews: