background image

AMERICAN-STANDARD ONE-YEAR LIMITED WARRANTY

If inspection of this American-Standard plumbing product, within one year after its initial installation, confirms that it is defective in materials or 

workmanship, American-Standard will repair or, at its option, exchange the product for a similar model. 

This warranty does not apply to local building code compliance.  Since local building codes vary considerably, the purchaser of this product should 

check with a local building or plumbing contractor to insure local code compliance before installation.

This warranty shall be void if the product has been moved from its initial place of installation; if it has been subjected to faulty maintenance, abuse, 

misuse, accident or other damage; if it was not installed in accordance with American-Standard's instructions; or if it has been modified in a manner 
inconsistent with the product as shipped by American-Standard.

American-Standard's option to repair or exchange the product under this warranty does not cover any labor or other costs of removal or installation, nor 

shall American-Standard be responsible for any other incidental or consequential damages attributable to a product defect or to the repair or 
exchange of a defective product, all of which are expressly excluded from this warranty.
 (Some states or provinces do not allow the exclusion or 
limitation of implied warranties, so this exclusion may not apply to you.)

This warranty gives you specific legal rights. You may have other statutory rights that vary from state to state or from province to province, in which case 

this warranty does not affect such statutory rights.

For service under this warranty, it is suggested that a claim be made through the contractor or dealer from or through whom the product was purchased, or 
that a service request (including a description of the product  model and of the defect) be sent  to the following address:

-   4   -

TROUBLESHOOTING GUIDE

NOTE:   The presence of a small amount of water in the bottom of the tank is normal. The air inducer is designed to leak 
for short periods during each flush cycle as a self-cleaning action.  Drippage is drained into the bowl. If used on water 
system containing excessive sand and/or debris, a periodic cleanup of inlet strainer is recommended. (See enclosed 

    instructions for strainer cleaning.) 

  

!     WARNING

When servicing  or replacing components of the flushometer tank system, be sure that the

water supply is shut off and the toilet is flushed to relieve pressure in the flushometer tank.

For service of the Flushometer Tank System, see enclosed literature.

     PROBLEM                 POSSIBLE CAUSE                                                  CORRECTIVE ACTION

 Does not flush

a.   Water supply valve closed.

a.   Open valve and allow water to fill tank.

b.   Flush actuator incorrectly set.

b.   Follow instruction to adjust flush actuator.

c.   Supply line blocked.

c.   Shut off water supply, disconnect supply line, and inspect

all gaskets and washers.  Reassemble.

d.

Trip lever linkage damaged.

d.   Check trip lever, linkage, and spring rod assemblies

for damage.

Poor or sluggish

a.  Supply valve partly closed.

a.   Open supply valve fully.  Be sure that proper supply tube

flush

     

size is used.

b.

Plugged inlet strainer.

b. Remove and clean strainer per enclosed instructions

c.   Supply pressure too low.

c.   Normal supply pressure must be at least 20 psi.

d.   Partially clogged trapway and/or

d.   Remove obstruction.  Consult a plumber if necessary.

      drain pipe and/or vent.
e.   Malfunctioning pressure regulator.

e.   Replace lower supply assembly.

Toilet leaks

a.   Poor supply line connection.

a.   Review Step 9 of installation procedure.

b.   Poor bowl to tank/floor connection.

b.   Review Step 4 through 7 of installation procedure.

Toilet does not

a.   Supply pressure too low.

a.   Normal supply pressure must be at least 20 psi.

shut off

b.   Flush actuator incorrectly set.

b.   Follow instructions to adjust flush actuator.

7 3 0 4 7 9 - 1 0 0   R e v .   A

In the United States:

American Standard Inc.,

P.O. Box 8305

Trenton, New Jersey 08650

Attention: Director of  Consumer Affairs

For residents of the United States,

warranty information may also be

obtained by calling the following

toll free number: (800) 442-1902

In Canada:

American-Standard, 

2480 Stanfield Road

Mississauga, Ontario 

Canada L4Y 1S2

Toll Free:  (800) 387-0369

In Mexico:

Customer Service Manager         

Ideal Standard, S.A. de C.V.

Via Morelos #330

Col. Santa Clara

Ecatepec 55540 Edo. Mexico

www.AmericanStandard-US.com

www.AmericanStandard.ca

www.AmericanStandard.com.mx

Summary of Contents for Cadet 1.6 GPF Two-Piece Pressure Assisted Toilets 2366

Page 1: ... Remove old mounting hardware remove toilet and plug floor waste opening to prevent escaping sewer gases d Remove closet bolts from flange and clean away old wax putty etc from base area NOTE Mounting surface must be clean and level before new toilet is installed 305mm 12 INSTALL CLOSET BOLTS Install closet bolts in flange channel turn 90 and slide into place 6 152 mm apart and parallel to wall S ...

Page 2: ... firmly seated on floor CAUTION DO NOT OVERTIGHTEN NUTS OR BASE MAY BE DAMAGED b Install caps on washers If necessary cut bolt height to size before installing caps c Smooth off the bead of sealant around base Remove excess sealant INSTALL TANK a Install large rubber gasket over threaded outlet on bottom of tank and lower tank onto bowl so that tapered end of gasket fits evenly into bowl water inl...

Page 3: ...ptions Specify when ordering ITEM PART NO DESCRIPTION QTY 1 2 3 4 5 6 7 8 9 10 11 1 1 1 1 1 1 1 1 1 1 1 1 1 738473 YYY0A 738494 YYY0A 4098 100 XXX 735083 400 XXX 3099 016 XXX 3083 016 XXX 3109 016 XXX 034783 XXX0A 738493 0070A 738495 0070A 004602 0070A 738496 0070A 047562 0070A 047563 0070A 730292 0070A 735083 600 XXX 603111 0030A TRIP LEVER LH TRIP LEVER RH TANK COMPLETE WITH COUPLING COMPONENTS ...

Page 4: ...a self cleaning action Drippage is drained into the bowl If used on water system containing excessive sand and or debris a periodic cleanup of inlet strainer is recommended See enclosed instructions for strainer cleaning WARNING When servicing or replacing components of the flushometer tank system be sure that the water supply is shut off and the toilet is flushed to relieve pressure in the flusho...

Reviews: