background image

CADENZA ELITE™ CORNER

WHIRLPOOLS BY AMERICAN STANDARD

HIGH GLOSS ACRYLIC

© 2003 American Standard Inc.

BATH CAN BE INSTALLED EITHER ABOVE OR BELOW FLOOR LINE AS PIER, ISLAND OR
PENINSULA TYPE INSTALLATION. SUPPORT OF BATH BY INTEGRAL FEET.  NO ADDITIONAL
SUPPORT REQUIRED. SUPPORT AND ENCLOSING MATERIAL BY OTHERS.

REFER TO INSTALLATION INSTRUCTIONS SUPPLIED WITH WHIRLPOOL FOR ADDITIONAL
INFORMATION.

OPTIONAL 2-WALL TILING BEAD KIT No.TILE-BEAD MUST BE ORDERED SEPARATELY.

CUTOUT TEMPLATE PROVIDED IN SHIPPING BOX.  MAY BE REQUESTED SEPARATELY.

PROVIDE SUITABLE REINFORCEMENT FOR ALL WALL SUPPORTS.

FITTINGS NOT INCLUDED, MUST BE ORDERED SEPARATELY.

IF INSTALLING A DECK-MOUNTED FITTING, BEFORE DRILLING ANY HOLES:  CHECK FOR
I N T E R F E R E N C E   W I T H   C I R C U L A T I N G   S Y S T E M   P I P I N G ,   D R A I N   O V E R F L O W ,   A N D   A P R O N
INSTALLATION.  MOUNTING HOLES DRILLED BY INSTALLER.

IMPORTANT: Dimensions of fixtures are nominal and may vary within the range of tolerances
established by ANSI Standard Z124.1
These measurements are subject to change or cancellation. No responsibility is assumed for use of
superseded or voided leaflet.

NOTES:

1949mm

(76-3/4 REF.)

546mm

(21-1/2)

ROUGH FLOOR

495mm

(19-1/2)

1384mm

(54-1/2)

1605mm

(63-3/16)

975mm

(38-3/8)

1661mm

(65-3/8)

  

346mm

(13-5/8)

SEAT AREA

254mm

(10)

114mm

(4-1/2)

PROVIDE ACCESS TO PUMP FOR SERVICE

ON ALL INSTALLATIONS

NOTE: APRON ASSEMBLY WILL PROVIDE REQUIRED

ACCESS FOR SERVICING

51mm
(2)

89mm

(3-1/2)

C/L OF OVERFLOW

LEVELING STRINGER
NOT FOR SUPPORT

PUMP

178mm x 381mm

(7 x 15) CUTOUT

C/L OF

DRAIN

143mm

(5-5/8)

OUTLINE OF

CUTOUT

C/L

ON/OFF SWITCH

83mm

(3-1/4)

1-1/2 N.P.T. THREAD

1-1/2 O.D. TAILPIECE

38mm

(1-1/2) 

INTEGRAL FEET
SUPPORT

RECOMMENDED FITTING 
LOCATION 64 X 381mm (2-1/2 X 15)

E-Z INSTALL WHIRLPOOL
HEATER

INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
WHIRLPOOL MIN. OPERATING VOL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.

CUBE (FT

3

)

GENERAL SPECIFICATIONS FOR 6060E WHIRLPOOL

WHIRLPOOL ELECTRICAL SPECIFICATIONS

PUMP 

76-3/4 x 65-3/8 x 21-1/2 In. (1949 x 1661 x 546mm)

105 Lbs. (48 Kg.)

822 Lbs. (370 Kg.)

86 Gal. (326 L)
71 Gal. (269 L)

45 x 40 In. (1143 x 1016mm)
49 x 43 In. (1245 x 1092mm)

15-3/8 In. (391mm)

24 Lbs./Sq.Ft. (114 Kgs./Sq.m)

41.7
68.4

  2.1 HP, 14.4 AMPS,120V.

E-Z INSTALL WHIRLPOOL HEATER 

12.0 AMPS,120V.