background image

M968602

5

Remove HANDLE (see step 3 and reverse).

Remove ESCUTCHEON and CARRIDGE CAP (see step 1 and reverse).
Shut off water supply by either closing off main water supply, or closing off
the hot and cold CHECK STOPS on valve.

TO GAIN ACCESS TO VALVE FOR SERVICING

Remove CARTRIDGE 

(1)

 by removing CARTRIDGE SCREWS 

(2)

. Remove three SCREWS 

(3)

 from FIXATION RING 

(4)

 and

pull out PRESSURE BALANCING 

(5)

 unit.

Clean SEALS 

(9)

 on base of CARTRIDGE 

(1)

. Check base of PRESSURE BALANCING UNIT 

(5)

 and clean O-RINGS 

(6)

. Remove

CAPS 

(7)

 and check O-RINGS on inside of CAPS 

(7)

. Clean inside sealing surfaces of VALVE BODY

 (8)

.

Re-assemble PRESSURE BALANCING UNIT 

(5)

 and CARTRIDGE 

(1)

. Tighten all screws.

Turn on water supply and see above for installing TRIM and HANDLE.

VALVE LEAKS WHEN SHUT OFF

BACK TO BACK INSTALLATION

BACK TO BACK INSTALLATION

ROTATE 180

˚

Remove PRESSURE BALANCE UNIT 

(5)

.

Remove CAPS 

(7)

 and clean valve thoroughly.

Examine balancing unit and check condition of O-ring on end of piston.  Piston should move back and forth.  Order Repair
Part M952100-0070A if balancing unit is defective.

Replace CAPS 

(7)

 and install PRESSURE BALANCE UNIT 

(5)

. Make sure inlets line up with two holes in bottom of casting.

Top flange should butt-up against top of casting.

Remove PRESSURE BALANCE UNIT 

(5)

. Rotate PRESSURE BALANCE UNIT 

(5)

 180˚ so that the inlets face up and the

large outlet port faces down.

Push PRESSURE BALANCE UNIT 

(5)

 in casting make sure inlets line up with holes in bottom of casting. Top flange should

butt up against top of casting.

Reassemble FIXATION RING 

(4)

 and CARTRIDGE 

(1)

.

UNABLE TO MAINTAIN CONSTANT TEMPERATURE

1

2

9

5

5

7

8

6

4

3

INLETS

LARGE OUTLET

6

15

13

11

97

53

10

 

15

1

3

1

1

9

7

5

3

1

 

1

5

1

3

1

1

9

7

5

3

1

 

COLDER

(Larger Numbers)

0 1 3 5 7 9 11 13 15

HOTTER

(Smaller Numbers)

0 1 3 5 7 9 11 13 15

ADJUST HOT LIMIT STOP

By restricting HANDLE rotation and limiting the amount of hot
water allowed to mix with the cold, the HOT LIMIT SAFETY
STOP 

(1)

 reduces risk of accidental scalding. To set the maximum

hot water temperature of your faucet, all you need to do
is adjust the setting on the HOT LIMIT SAFETY STOP 

(1)

.

4

Turn CARTRIDGE STEM 

(2)

 to the OFF position (coldest setting) before

making adjustment to HOT LIMIT STOP 

(1)

. Use aflat blade screwdriver to pry

free the HOT LIMIT SAFETY STOP 

(1)

. Pull forward and rotate counterclockwise

one number to limit hot water temperature. Use ARROW 

(3)

 on CARTRIDGE 

(4)

and NUMBERS 

(5)

 on HOT LIMIT STOP 

(1)

 for indication.

1

5

4

3

1

5

4

3

2

2

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH  CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.

DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.

CARE INSTRUCTIONS:

Reviews: