American Standard BERWICK M968641 Installation Instructions Manual Download Page 4

M 9 6 8 6 4 1   R E V. 1 . 2

1

4

10

TEST INSTALLED FITTING

With HANDLE 

(1)

 in OFF position, turn on WATER

SUPPLIES 

(2)

 and check all connections for leaks.

Remove AERATOR 

(3)

.

Operate HANDLE 

(1)

 to flush water lines thoroughly.

Replace AERATOR 

(3)

.

3

CHECK DRAIN CONNECTIONS

Operate POP-UP KNOB 

(4)

 and fill lavatory with water.

Check that DRAIN STOPPER 

(5)

 makes a good seal

and retains water in Sink. If DRAIN STOPPER 

(5)

does not seal properly, please refer to Troubleshooting

section in these instructions.

Release POP-UP KNOB 

(4)

 down and check all drain

connections and "P" trap for leaks.     Tighten

if necessary.

12

4

OFF

ON

HOT

COLD

5

“P” TRAP

WASTE

OUTLET

2

2

CARE INSTRUCTIONS:

1

2

2.5mm HEX KEY

3

8

4

A

B

D

5

6

REMOVE

INSTALL

7

10

11

SERVICE

To remove or replace cartidge:

To adjust HOT LIMIT SAFETY STOP:

Turn valve to OFF position.

Pull out PLUG BUTTON 

(1)

 and remove HANDLE SCREW 

(2)

.  

Pull off HANDLE 

(3)

 and CAP 

(4)

.

Unthread CARTRIDGE NUT 

(5)

 and remove.

Pull out CARTEIDGE 

(6)

.

Inspect CARTRIDGE 

(6)

 and O-RINGS 

(7)

 for debris and

clean if necessary.

Clean MANIFOLD 

(8)

 and rinse clean.

Reinstall CARTRIDGE 

(6)

 and O-RINGS 

(7)

 onto MANIFLOD 

(8)

.

Reinstall CARTRIDGE NUT 

(5)

, CAP 

(4)

 and HANDLE ASSEMBLY 

(3)

.

If spout drips, operate handle several times from OFF to ON and

HOT to COLD position. Do not force - handle turns only 90˚.

Turn off hot and cold water

supplies before beginning.

CAUTION

By restricting HANDLE rotation and limiting the amount of hot

water allowed to mix with the cold, the HOT LIMIT SAFETY

STOP 

(9)

 reduces risk of accidental scalding. To lower the

maximum hot water temperature of your faucet, all you need

to do is adjust the setting on the HOT LIMIT SAFETY STOP 

(9)

.

Note: The HOT LIMIT SAFETY STOP (9) is set at the maximum

hot temperature setting from the factory. Fig. A.

 

ADJUST HOT LIMIT SAFEYT STOP

Remove HANDLE ASSEMBLY 

(3)

, CAP 

(4)

 and CARTRIDGE NUT 

(5)

.

Set the CARTRIDGE STEM 

(10)

 to the OFF position and rotate it

clockwise until stops. 

Fig. B.

Rotate the CARTRIDGE STEM 

(10)

 counter-clockwise to a colder

setting mark in the HOT LIMIT SAFETY STOP 

(9)

Fig. C.

Lift up the HOT LIMIT SAFETY STOP 

(9)

 and rotate it to coincide

again with the stop in the base of the CARTRIDGE STEM 

(10)

Fig. D.

Replace the HOT LIMIT SAFETY STOP 

(9)

.

Reinstall CARTRIDGE NUT 

(5)

, CAP 

(4)

 and HANDLE ASSEMBLY 

(3)

.

GEAR

GEAR

GEAR

10

9

9

C

10

9

+HOTTER

SETTING

MARKS

COLDER

GEAR

10

9

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH  CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A

CLOTH WITH A COARSE SURFACE.

Summary of Contents for BERWICK M968641

Page 1: ... collar facing up into groove in faucet base From below push GASKET 7 and RETAINING WASHER 5 onto MOUNTING STUD 4 Secure Faucet with MOUNTING NUT 6 pulling faucet to front of sink so SUPPLIES 3 rests against mounting hole Before final tightening make sure collar on MOUNTING NUT 6 is seated into RETAINING WASHER 5 Figure B Adjust Faucet so that it is centered Tighten MOUNTING NUT 6 to complete fauc...

Page 2: ... Adjustable Wrench or Channel Locks INSTALL DRAIN FROM BELOW FIXTURE 5 From under side of SINK install DRAIN BODY 1 up through drain outlet Note No plumber s putty or caulk is required The CABLE ATTACHMENT POINT 2 must face towards the rear of the SINK Install FOAM GASKET 3 and FLANGE 4 onto drain body from above SINK and tighten FLANGE 4 firmly 4 Fig A Fig B Fig B POP UP KNOB 1 must be fully down...

Page 3: ...on pop up drain is 1 1 4 O D Fig B Fig A ATTACH CABLE CONNECTOR 7 2 1 Fig B 1 1 4 O D 3 1 1 APPROX 20 2 COLD HOT 3 8 COMPRESSION RED BAND BLUE BAND Connect FLEXIBLE SUPPLIES 1 2 directly to wall supplies Connection on fitting supplies are 3 8 compression Connect left SUPPLY 1 to Hot Marked with a Red Band and right supply to COLD 2 wall supply Faucet supplies are 20 long from faucet base Note If a...

Page 4: ...3 If spout drips operate handle several times from OFF to ON and HOT to COLD position Do not force handle turns only 90 Turn off hot and cold water supplies before beginning CAUTION By restricting HANDLE rotation and limiting the amount of hot water allowed to mix with the cold the HOT LIMIT SAFETY STOP 9 reduces risk of accidental scalding To lower the maximum hot water temperature of your faucet...

Page 5: ...ollow CABLE ADJUSTMENT PROCEDURE If you need to remove the Stopper Follow STOPPER REMOVAL PROCEDURE If you would like the ability to remove your Stopper simply by lifting it out of the drain Follow STOPPER INSTALLATION PROCEDURE for Unlocked mode Fig B Fig A REMOVE CAM Fig E Fig F Disconnect the Cable from the Drain by threading the Cable Connector 1 counter clockwise Fig A Look at the area on the...

Page 6: ...k at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig H To install the stopper in Unlocked mode insert the Stopper into the Drain so that the Plastic Loop is facing toward the front of the Sink and the American Standard logo is facing rear Rotate Stopper slightly if necessary so that the Stopper slides all the way down Fig H Re install the Ca...

Reviews: