background image

M 9 6 8 6 4 2

Turn off hot and cold water

supplies before beginning.

CAUTION

OFF

ON

COLD

HOT

4

5

TEST INSTALLED FAUCET

AND CHECK FOR LEAKS

SERVICE

1

2

3

COLD

HOT

With HANDLE 

(1)

 in OFF position, turn on WATER

SUPPLIES 

(2)

 and check all connections for leaks.

Remove AERATOR 

(3)

.

Operate HANDLE 

(1)

 to flush water lines thoroughly.

Replace AERATOR 

(3)

.

6

1

2

4

5

6

2.5mm HEX KEY

REMOVE

INSTALL

7

8

To remove or replace cartidge

Turn valve to OFF position.
Pull out PLUG BUTTON 

(1)

 and remove HANDLE SCREW 

(2)

.  

Pull off HANDLE 

(3)

 and CAP 

(4)

.

Unthread CARTRIDGE NUT 

(5)

 and remove.

Pull out CARTEIDGE 

(6)

.

Inspect CARTRIDGE 

(6)

 and O-RINGS 

(7)

 for debris and clean 

if necessary.
Clean MANIFOLD 

(8)

 and rinse clean.

Reinstall CARTRIDGE 

(6)

 and O-RINGS 

(7)

 onto MANIFLOD 

(8)

.

Reinstall CARTRIDGE NUT 

(5)

, CAP 

(4)

 and HANDLE ASSEMBLY 

(3)

.

If spout drips, operate handle several times from OFF to ON and HOT to
COLD position. Do not force - handles turn only 90˚.

3

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH  CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.

DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.

CARE INSTRUCTIONS: