background image

H160

© 2008 AS America Inc.

NOTES:

RIGHT HAND OUTLET SHOWN, RIGHT HAND REVERSE DIMENSIONS 

(2697.102).

PROVIDE SUITABLE REINFORCEMENT FOR ALL WALL SUPPORTS.

FITTINGS NOT INCLUDED AND MUST BE ORDERED SEPARATELY.

■ 

REFER TO INSTALLATION INSTRUCTIONS SUPPLIED WITH BATH.

IMPORTANT:  Dimensions of fixtures are nominal and may vary within the range 

of tolerances established by ANSI Standard A112.19.1. These measurements 

are subject to change or cancellation. No responsibility is assumed for use of 

superseded or voided leaflet.

To Be Specified:

  Color:

  Bath Faucet*:

  Faucet Finish:

❏ 

 Drain: 1583.470

* See faucet section for additional models available

BELMOR™

5' TUB 

ENAMELED CAST IRON

BELMOR™ 5' CAST IRON TUB

❏ 

2697.102  Right hand outlet

 ❏ 

2697.202  Left hand outlet 

 

Product Features:

 

• Enameled cast iron construction

 

• One-piece bath

 

• Integral apron

 

• Comfortable lumbar support

 

• End drain outlet

 

• Full slip-resistant pattern

Nominal Dimensions:
60" x 30" x 14"
(1524 x 762 x 356mm) 

Compliance Certifications -
Meets or Exceeds the Following Specifications:
• ASME A112.19.1 for Cast Iron Plumbing Fixtures
• ASTM F-462 for Slip-resistant Bathing Facilities
• CAN / CSA B45 Series

SUPPORT

FEET

 

ROUGH

FLOOR

FINISHED

WALL

229 x 305mm

9" X 12" HOLE IN SUB FLOOR

FOR BELOW FLOOR ROUGH

762mm

30"

1524mm

60"

381mm

15"

FINISHED

WALL

FINISHED

WALL

FINISHED

WALL

206mm

8-1/2"

356mm

14"

64mm

2-1/2"

DIA.

6mm

1/4"

13mm

1/2"

76mm

3"

STD. 1-1/2

DRAIN OUTLET

38mm

1-1/2"

GENERAL SPECIFICATIONS FOR 2697 BATHING POOL

60 x 30 x 14 In. (1524 x 762 x 356mm)

430 Lbs. (195 Kg.)
715 Lbs. (320 Kg.)

34 Gal. (128 L)

42 x 18 In. (1066 x 457mm)
24 x 55 In. (610 x 1397mm)

10 In. (254mm)

60 Lbs./Sq.Ft. (293 Kgs./Sq.m)

12.5

INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA FT

2

)

MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES 

AND ANSI A117.1 REQUIREMENTS FOR ACCESSIBLE AND 

USEABLE BUILDING FACILITIES-CHECK LOCAL CODES.

INSTALL WITH SEAT AT HEAD END.

Revised 2/08

BARRIER FREE

Reviews: