background image

                                                                                       ACTICLEAN

™ 

 

----------------------------------------------------------------     2     ---------------------------------------------------------------- 

Product names listed herein are trademarks of AS America  Inc.                                                                                                                            7302224-100 (06/16)

 

© AS America Inc. 2014

 

 

FLUSH VALVE ASSEMBLY 
P/N: 7381557-400.0070A

 

 
TO RE-INSTALL:

 

• Install the valve, orient valve assembly so 

overflow funnel is positioned towards the 
back of the tank (see 

FIGURE 4

)

 

• Hold the valve in the tank with one hand

 

• Place friction washer over threads on bottom 

of the tank (see 

FIGURE 5

)

 

• Attach nut; orientation tabs must face away 

from tank (see 

FIGURE 6

)

 

• Use supplied tool to tighten nuts to tank 

bottom, at least one hand tight

 

• Apply and work gaskets around the 6 

retaining tabs on the nut so the inner rib on 
the gasket is captured between the tabs and 
the tank. Note the inner rib on the gasket is 
offset to one side. Be sure to orient the 
gasket with the inner rib towards the bottom 
of the tank. When done correctly, the gasket 
should not be compressed and should be 
held in place while installing the tank.

 

• Re-mount tank to bowl (see 

FIGURE 1

)

 

• Re-attach the refill tube into the overflow 

funnel connection of the new valve

 

• Insert the BLACK trip lever arm in to the 

chain coupler of the bead chain;  push the 
clevis pin through the arm and insert the hair 
pin (see 

FIGURE 3

)

 

• Insert the RED trip lever arm in to the yoke 

of the teeter bar; push the clevis pin through 
the arm and insert the hair pin (see 

FIGURE 

3

)

 

 

 
 
 
 
 
 

 

FIGURE 4 

Reviews: