ACONT802AS32DA TOUCH SCREEN AND ACONT803AS32DA TOUCH SCREEN WITH DEHUMIDIFICATION
69-1788—03
14
Deadband
0310
2 thru 9 Heating and cooling
setpoints can be set
no closer than chosen
value:
2
—2
°
F (1
°
C)
3
—3
°
F (2
°
C)
4
—4
°
F (2.5
°
C)
5
—5
°
F (3
°
C)
6
—6
°
F (3.5
°
C)
7
—7
°
F (4
°
C)
8
—8
°
F (4.5
°
C)
9
—9
°
F (5
°
C)
3
Heating and cooling setpoints
can be set no closer than 3
°
F
(1.5
°
C).
Shown only if
automatic
changeover is
selected.
The deadband is
restricted to the range
of 5 to 9 if ISU 0380 is
set to
dehumidification
droop control.
Temperature
Indication
Scale
0320
0
Temperature is
displayed in
°
F.
1
Temperature is displayed in
°
C.
—
Daylight
Savings
0330
1
Daylight savings
enabled (use through
2006 and for areas
that do not use the
new 2007 DST
calendar).
0, 2
0
—daylight savings is
disabled.
2
—daylight savings enabled
(use starting in 2007 for areas
that use the new 2007 DST
calendar).
Set to 0 in areas that
do not follow daylight
savings.
Remote
Temperature
Sensor
(Outdoor or
Indoor)
0340
0
No remote
temperature sensor.
1-3
1
—outdoor temperature
sensor for display only.
2
—outdoor temperature
sensor for system control—
used for select heat pump
systems. (See Special Heat
Pump Features section for
more details.)
3
—indoor temperature sensor
Defaults and Options
depend on System
Type selection.
Indoor Temperature
Sensor uses an
averaging network
and does not include
on-board sensor.
Heat Pump
Compressor
Lockout
0350
0
No compressor
lockout.
15, 20,
25, 30,
35, 40,
45
15
°
F (-9.5
°
C)
20
°
F (-6.5
°
C)
25
°
F (-4
°
C)
30
°
F (-1
°
C)
35
°
F (1.5
°
C)
40
°
F (4.5
°
C)
45
°
F (7
°
C)
Default depends on
other selections.
Shown if Outdoor
Temperature for
control is selected.
Heat Pump
Auxiliary
Lockout
0360
0
No heat pump
auxiliary lockout.
40, 45,
50, 55,
60
40
°
F (4.5
°
C)
45
°
F (7
°
C)
50
°
F (10
°
C)
55
°
F (13
°
C)
60
°
F (15.5
°
C)
Shown if electric is
chosen for backup
heat source and
outdoor temperature
sensor for control is
selected.
Indoor
Dehumidificati
on Control
0380
0
No indoor
dehumidification
control.
1
1
—dehumidification droop
control.
Available on models
with humidity sensor.
Furnace Filter
Change
Reminder
0500
0
Furnace filter change
reminder off.
1-6
1
—10 run time days
2
—30 run time days
3
—60 run time days
4
—90 run time days
5
—120 run time days
6
—365 run time days
Run time based on
call for fan.
Humidifier
Pad
Replacement
Reminder
0510
0
Humidifier pad
replacement reminder
off.
1-3
1
— 90 calendar days
2
—180 calendar days
3
—365 calendar days
—
Table 4. Installer Setup Menu. (Continued)
Select
Installer
Setup
Number
Factory Setting
Other Choices
Comments
Option
Description
Options
Description