Introduction: Thank you for selecting our products...products which have been the 

benchmarks of fine quality for years.  To help insure that the installation process will 

proceed smoothly, please read these instructions carefully before you begin.  Also, 

review the recommended tools and materials list; carefully unpack and examine your 

new plumbing fixture.

Channel Lock Pliers

Regular Screwdriver

Recommended Tools & Materials

Rough-In

Dimensions

Phillips Screwdriver

Pipe Wrench

Drill

Plumbers' Putty or Caulking

Tubing Cutter

Tape

Measure

Hacksaw

Pencil

Torch

Level

S

A

VE FOR FUTURE USE

CAUTION: PRODUCT IS FRAGILE. TO AVOID DAMAGE AND POSSIBLE INJURY HANDLE WITH CARE!

NOTE: 

Pictures may not exactly define contour of china and components.

ICU Sink System

Models: 9118.111, 9118.100 & 9118.150

INSTALLATION INSTRUCTIONS

!

P r o d u c t   n a m e s   l i s t e d   h e r e i n   a r e   t r a d e m a r k s   o f   A S   A m e r i c a ,   I n c .
©   A S   A m e r i c a ,   I n c .   2 0 1 2

14-3/4"

(375mm)

17"

(432mm)

4-3/4"

(121mm)

5/8"

(14mm)

1-5/8"

(41mm)

20"

(509mm)

4-3/4"

(120mm)

8" (203mm)

 1/2" DIA.

(13mm)

FINISHED WALL

BASE MOUNT

DETAIL

FINISHED

FLOOR

FINISHED

FLOOR

FINISHED

FLOOR

26-1/8"

(663mm)

36"

(914mm)

36-1/2"

(927mm)

36-1/2"

(927mm)

40-1/8"

(1020mm)

2-3/4"

(70mm)

9/16" DIA.

(14mm)

2-3/4"

(70mm)

4"

(102mm)

4"

(102mm)

MOUNTING

STUDS

Adjustable Wrench

*

FAUCET PERCH

2-1/2" DIA. (65mm)

*

FAUCET PERCH

2-1/2" DIA. (65mm)

                

*DISCLAIMER:  Faucets with a base diameter greater than 2-1/4" (57 mm) will not fit on this 

ICU Sink. The Selectronic ICU Faucet was specifically designed to minimize splashing during 

operation.  American Standard will not be liable for any splashing that occurs if faucets other 

than the American Standard ICU Faucets are used.  

8"(203mm) BETWEEN

MOUNTING HOLES

RECOMMENDED CARRIERS:

JAY R. SMITH MFG. CO.
MODEL SQ-0-4437  
FLOOR MOUNTED SINK SUPPORT

WATTS CA-311 
FLOOR MOUNTED URINAL CARRIER 

Summary of Contents for 9118.111

Page 1: ... INSTALLATION INSTRUCTIONS Pr o d u c t n a m e s l i s t e d h e r e i n a r e t r a d e m a r k s o f A S A m e r i c a I n c A S A m e r i c a I n c 2 01 2 14 3 4 375mm 17 432mm 4 3 4 121mm 5 8 14mm 1 5 8 41mm 20 509mm 4 3 4 120mm 8 203mm 1 2 DIA 13mm FINISHED WALL BASE MOUNT DETAIL FINISHED FLOOR FINISHED FLOOR FINISHED FLOOR 26 1 8 663mm 36 914mm 36 1 2 927mm 36 1 2 927mm 40 1 8 1020mm 2 3 4 ...

Page 2: ...f mounting surface 2 Assemble C WASHER 4 STAR WASHER 5 and LOCKNUT 6 onto threads of SPOUT SHANK 3 from underside of mounting surface 3 Align FAUCET and tighten LOCKNUT 6 1 Apply plumber s putty to the underside of flange Install GRID DRAIN into drain outlet 2 From the underside of SINK install RUBBER GASKET flat side up and FRICTION GASKET onto GRID DRAIN threads Apply sealent to threads of GRID ...

Page 3: ... BRACKET Replace NYLOCK NUT WASHER tighten both ends Do not over tighten chinaware could become damaged NYLOCK NUT AND WASHER HANGER STUD COLD WATER OR TEMPERED WATER 3 8 SUPPLY HOT MIXING VALVE MIXING VALVE SCREWS MOUNTING PLATE ELECTRONIC BOX ELECTRONIC BOX COLD 1 2 1 Connect SUPPLY NUT 1 from SPOUT assembly to nipple on top of ENCLOSURE 2 Tighten with adjustable wrench to make a water tight con...

Page 4: ...e COVER from MIXING VALVE 2 Install FIBER SEAL WASHER 4 on MIXING VALVE NIPPLE 3 Hold MIXING VALVE 1 in place with one hand and with your other hand thread SWIVEL NUT 2 onto MIXING VALVE NIPPLE 3 Use an adjustable wrench to tighten SWIVEL NUT 2 3 Place MIXING VALVE BOX onto MOUNTING PLATE Align BOX with mounting holes Attach with SCREWS provided 4 Replace COVER and tighten securely NOTE For comple...

Page 5: ...ea only 1 905 3061093 SELECTRONIC Proximity ICU Faucet Certified to comply with ASME A112 18 1M 2011 American Standard To learn more about American Standard Faucets visit our website at www us amstd com or U S customer s e mail us at faucetsupport amstd com For Parts Service Warranty or other Assistance please call 1 800 442 1902 In Canada 1 800 387 0369 NOTE TO INSTALLER Please give this manual t...

Page 6: ...TING SCREWS AND ANCHORS NOT SUPPLIED Use Brackets to mark pilot holes on wall Drill holes for ANCHORS Peel off the protective strip from the back of the APRON BRACKETS Apply the two APRON BRACKETS to the finished wall parallel to the pencil marks as shown and aligned with the mounting holes See illustration below Install SCREWS and tighten 4 Clean off the pencil marks from wall 6 152mm APRON SINK ...

Page 7: ...E LIABLE FOR THE COST OF REPAIR OR REPLACEMENT OF ANY INSTALLATION MATERIALS INCLUDING BUT NOT LIMITED TO TILES MARBLE ETC American Standard will not be responsible for any other incidental or consequential damages attributable to a product defect or to the repair or exchange of a defective product all of which are expressly excluded from this limited warranty This limited warranty does not cover ...

Reviews: