Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years.
To ensure that your installation proceeds smoothly--please read these instructions carefully
before you begin.

Installation Instructions

ROUGHING-IN DIMENSIONS

7271.301

7271.300

7271.521

7271.571

7271.021

7271.521

7271.021

7271.071

7271.571

7271.071

7271.400

7271.400

LABORATORY FUME HOOD FITTINGS

 DIA.

[32mm]

1-1/4"

[89mm]

3-1/2"

 DIA.

[54mm]

2-1/8"

[57mm]

2-1/4"

1-3/4"

[45mm]

[24mm]

15/16"

[67mm]

2-5/8"

 3/8" NPT FEMALE
 THREAD OUTLET

3/8" NPT

FEMALE 

THREAD INLET 

 INDEX AS REQUIRED
 (AIR, GAS, OR VAC)

DIA.

[32mm]

1-1/4"

1/16"-

[2mm-32mm]

WARE THICKNESS

1-1/4"

1/16"-

[2mm-32mm]

WARE THICKNESS

1-1/4"

[89mm]

3-1/2"

 DIA.

[54mm]

2-1/8"

[57mm]

2-1/4"

[24mm]

15/16"

1-3/4"

[45mm]

[57mm]

2-1/4"

 3/8" NPT FEMALE
 THREAD OUTLET

3/8" NPT FEMALE 

THREAD INLET 

 INDEX 'CW' 

PANEL THICKNESS
NOT TO EXCEED

[3mm]

1/8"

45

˚

3"

[76mm]

1-3/4"

[44mm]

[44mm]

1-3/4"

[51mm]

IA. FLANGE

2"

[32mm]

1-1/4"

[7mm]

9/32"

1-5/8" [41mm]
HEX. NU

LOCK DO

PROVIDE 1-1/2" [38mm] DIA.
OPENING IN PANEL TO ACCEPT
1-7/16" [37mm] DIA. BODY

IN

 OUT

NOTE:

INLET ALWAYS
ON BOTTOM

3/8" NPT FEM.

INLET THRD.

3/8" NPT FEM.
OUTLET THRD.

INDEX AS REQUIRED

(AIR, GAS, VAC)

[54mm]

2-1/8"

1/16"-

[2mm-32mm]

WARE THICKNESS

1-1/4"

 [54mm]

DIA. FLANGE

2-1/8

DIA.

[17mm]

11/16"

"

[102mm]

4

3/8" NPT MALE
THREAD INLET

Product names listed herein are trademarks of American Standard Inc.  © A m e r i c a n   S t a n d a r d   I n c .   2 0 0 4

HOTLINE FOR HELP

For toll-free information and answers to your questions, call:

1 (800) 442-1902

Weekdays

8:00 to 7:00 p.m. Eastern Time

CANADA

1-800-387-0369   (TORONTO 1-905-306-1093)

Summary of Contents for 7271

Page 1: ...9mm 3 1 2 DIA 54mm 2 1 8 57mm 2 1 4 24mm 15 16 1 3 4 45mm 57mm 2 1 4 3 8 NPT FEMALE THREAD OUTLET 3 8 NPT FEMALE THREAD INLET INDEX CW PANEL THICKNESS NOT TO EXCEED 3mm 1 8 45 3 76mm 1 3 4 44mm 44mm 1 3 4 51mm IA FLANGE 2 32mm 1 1 4 7mm 9 32 1 5 8 41mm HEX NU LOCK DO PROVIDE 1 1 2 38mm DIA OPENING IN PANEL TO ACCEPT 1 7 16 37mm DIA BODY IN OUT NOTE INLET ALWAYS ON BOTTOM 3 8 NPT FEM INLET THRD 3 8...

Page 2: ... 5 3 8 114mm 4 1 2 279mm 11 Adjustable Wrench Channel Locks Flat Blade Screwdriver Phillips Screwdriver Pipe Wrench Teflon Tape Plumbers Putty or Caulking 1 2 3 4 FRONT LOADED VALVE FOR ANGLED PANELS AIR GAS VACUUM WATER FRONT LOADED VALVE FOR STRAIGHT PANELS AIR GAS VACUUM OR WATER TYPICAL FUME HOOD FUME HOOD FITTINGS WALL MOUNTED REMOTE CONTROL OUTLET FITTING For installation of products refer t...

Page 3: ...E VALVE HOOD MOUNTING HOLE CROSS HANDLE CAP NUT PACKING NUT 7271 571 and 7271 521 ONLY INSTALL FRONT LOADED ANGLE CONTROL VALVE 7271 021 521 AIR GAS VACUUM WATER INSTALL FRONT LOADED VALVE FOR STRAIGHT PANELS 7271 071 571 AIR GAS VACUUM WATER HANDLE SCREW NDEX BUTTON STEEL WASHER RUBBER WASHER BODY FIGURE 1 SHOULDER WASHER 1 1 2 38 1mm MOUNTING HOLE HOLD DOWN NUT Remove and flange from valve Rubbe...

Page 4: ... nipple length from side wall Turn spout nut counter clock wise to loosen and remove spout assembly from fitting base pipe nipple See rough in for piping requirements Thread spout body onto y pipe nipple and align so that spout assembly is vertical Thread spout assembly onto y spout body and tighten y Turn supply to fitting on and check for leaks FUME HOOD WALL FUME HOOD WALL VACUUM BREAKER REPAIR...

Reviews: