AS AMERICA, INC. (“AMERICAN STANDARD”) ONE-YEAR LIMITED WARRANTY

If inspection of this AS America, Inc. (“American Standard”) plumbing product, within one year after its initial 

purchase, confirms that it is defective in materials or workmanship, American-Standard will repair or, at its option, 
exchange the product for a similar model. 

This warranty

 does not apply

 to local building code compliance. Since local building codes vary considerably, 

the purchaser of this product should check with a local building or plumbing contractor to insure local code 
compliance before installation.

This warranty 

shall be void

 if the product has been moved from its initial place of installation; if it has been 

subjected to faulty maintenance, abuse, misuse, accident or other damage; if it was not installed in accordance with 
American Standard's instructions; or if it has been modified in a manner inconsistent with the product as shipped by 
American Standard.

American Standard's option to repair or exchange the product under this warranty does not cover any labor or 

other costs of removal or installation, 

nor shall American Standard be responsible for any other incidental or 

consequential damages attributable to a product defect or to the repair or exchange of a defective product, 
all of which are expressly excluded from this warranty.

 (Some states or provinces do not allow the exclusion or 

limitation of implied warranties, so this exclusion may not apply to you.)

This warranty gives you specific legal rights. You may have other statutory rights that vary from state to state or 

from province to province, in which case this warranty does not affect such statutory rights.

For service under this warranty, it is suggested that a claim be made through the contractor or dealer from or 
through whom the product was purchased, or that a service request (including a description of the product  model 
and of the defect) be sent  to the following address:

TROUBLESHOOTING GUIDE

 

         PROBLEM                    

                          POSSIBLE CAUSE                                                                                      CORRECTIVE ACTION

       Does not flush 

a.  Water supply valve closed. 

  a.  Open valve and allow water to fill tank.

 

b.  Supply line blocked. 

  b.  Shut off water supply, disconnect supply line, and inspect

 

 

 

       all gaskets and washers.  Reassemble. Also, see Fluidmaster

 

 

 

       maintenance (see step 13).

 

c.  Flush valve chain too loose or disconnected. 

  c.  Readjust chain length as required.

 

     

 

d.  Sand or debris lodged in water control. 

  d.  Shut off water supply. Remove cap and clean per Step 13.

 

 

 

 

  Poor or  sluggish flush 

a.  Bowl water level too low. 

  a.  Check that refill tube is connected to water control and

 

 

 

       inserted into tank overflow without being kinked or damaged.

 

b.  Supply valve partly closed. 

  b.  Open supply valve fully. Be sure that proper supply tube size is used.

 

c.  Partially clogged trapway and/or drain pipe and/or vent. 

  c.  Remove obstruction. Consult a plumber if necessary.

 

     

 

d.  Supply pressure too low. 

  d.  Normal supply pressure must be at least 20 psi.

          Toilet leaks 

a.  Poor supply line connection. 

  a.  Review Step 9 of installation procedure.

 

b.  Poor bowl to tank/floor connection. 

  b.  Review Step 4 through 7 of installation procedure.

  Toilet does not shut off 

a.  Flush valve chain too tight, holding flush valve open. 

  a.  Readjust chain length as needed. Review step 10.

 

b.  Flush valve seat and/or flapper worn or deformed. 

  b.  Replace flapper/flush valve assembly, as needed.

 

c.  Sand or debris lodged in water control.  

  c.  Shut off water supply. Remove cap and clean per Step 13.

-   5   -

In the United States:

American Standard Brands

P.O. Box 6820

Piscataway, New Jersey 08855

Attention: Director of  Consumer Affairs

For residents of the United States, warranty information 

may also be obtained by calling the following 

toll free number: (800) 442-1902

In Canada:

AS Canada ULC

2480 Stanfield Rd.

Mississauga, Ontario 

Canada L4Y 1S2

Toll Free:  (800) 387-0369

In Mexico:

Customer Service Manager 

AS Maquila, S.A. de C.V.

Via Morelos #330

Col. Santa Clara

Ecatepec 55540 Edo. Mexico

www.americanstandard-us.com

www.americanstandard.ca

www.americanstandard.com.mx

Summary of Contents for 2446

Page 1: ... n a m e s l i s t e d h e r e i n a r e t r a d e m a r k s o f A S A m e r i c a I n c A S A m e r i c a I n c 2 0 0 8 NOTE Pictures may not exactly define contour of china and components ROUGHING IN DIMENSIONS NOTE Distance from wall to closet flange centerline must be as listed below A 12 305mm A WAX RING SEALANT 5 4 INSTALL WAX SEAL Invert toilet on floor cushion to prevent damage and install...

Page 2: ...erly reconnect the water supply DO NOT use plumber s putty to seal these fittings CAUTION DO NOT USE CONE WASHER WITH PLASTIC SUPPLY LINE These parts must be used as illustrated to insure water tight connection Use of existing coupling nut may result in water leakage Water supply tube or pipe must extend at least 1 2 inside threaded shank of valve does not apply to flanged tubing Use existing coup...

Page 3: ... not use in tank cleaners Products containing chlorine calcium hypochlorite can seriously damage fittings in the tank This damage can cause leakage and property damage American Standard shall not be responsible or liable for any tank fitting damage caused by the use of cleaners containing chlorine calcium hypochlorite 4392 W LINER 4037 W LINER 4037 4392 ADJUSTMENTS a Adjust water level Water level...

Page 4: ...ank ball or flapper replace with a new flapper IF FILL VALVE WON T TURN ON OR SHUT OFF or REFILL OF TANK WATER IS SLOW after valve has been in use for some time Fluidmaster Model 242 Replacement Seal may be needed Go to our website at www fluidmaster com for more solutions to toilet problems 2001 Fluidmaster Inc Registered trademark of Fluidmaster Inc GUARANTEE This Fluidmaster product is guarante...

Page 5: ...e product model and of the defect be sent to the following address TROUBLESHOOTING GUIDE PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION Does not flush a Water supply valve closed a Open valve and allow water to fill tank b Supply line blocked b Shut off water supply disconnect supply line and inspect all gaskets and washers Reassemble Also see Fluidmaster maintenance see step 13 c Flush valve chain too ...

Reviews: